11
J35B-L / J35D
TERMINAL/LOAD
CURRENT RATING
J35B-L / J35D
TERMINAL/LOAD
CURRENT RATING
1-Slide-Out
15A
8-12V Outlet 1
10A
2-Spare 2
15A
9-12V Outlet 2
10A
3-Water Pump
10A
10-Spare 10
10A
4-Hot Water
10A
11-Spare 11
10A
5-Lights 1
10A
12-Spare 12
15A
6-Lights 2
10A
13-AirSusp ECU
10A
7-Lights 3
10A
14-Tablet
5A
Table 4:
J35B-L
and
J35D
designated terminal-load outputs for the load
terminal block-positive connection
Each output is protected by an internal, electronic, auto-recoverable fuse. This
eliminates the need for the user to replace a blown fuse. If an electronic fuse is
activated, the LED Status Indicator on the J35 will flash a solid red. The J35 will
power off the faulty load and resume normal operation once the fault is fixed.
r
FAN
Regulates the internal temperature of the J35.
WARNING
To ensure continuous air-flow, the fan ventilation holes must never be blocked,
otherwise the temperature of the J35 may rise and inhibit the optimal operation of the
J35 and/or cause the J35 to shut down. The J35 will automatically restart once it has
cooled to an acceptable level.
WARNING
The Air Suspension output is not controlled by the Load Isolation Switch circuitry.
Engaging Load Isolation will not affect the operation of the caravan’s Air Suspension.
t
LED STATUS INDICATOR
Indicates the operational status of the J35.
y
AIR SUSPENSION OUTPUT (J35D)
Connection point to power the caravan’s air suspension.