LOAD BEARING DATA
Diagram B
Diagram A
COMPONENT WEIGHTS
Approximate Weights of Finished Goods
(Kg)
Int. Diameter Length
(mm)
100mm
125mm
150mm
180mm
200mm
1460
-
11.9
12.9
16.5
17.8
960
5.78
7.1
7.9
9.8
10.6
460
4.18
3.7
4.2
5.1
5.5
293
3.64
2.3
2.6
3.4
3.7
160
3.32
1.5
1.8
2.2
2.3
Maximum Load Bearing
(metres of pipe)
Internal Diameter
(mm)
Base Drain Section
Top Plate with Drain
Top Plate and Locking Band
Pair or Side Plates (see diagram A)
Pair or Side Plates (see diagram B)
Cantilever Support
Extension Support (Anchor Plate)
Ventilated Support Plate (All types)
Support Plate
Wall Band 50mm
Adjustable Wall Band 75-300mm
Structural Wall Band
Extension for Structural Wall Band
Roof Support (above truss)
Roof Support (below truss)
Guy Wire Bracket
90° Tee + Locking Band
135° Tee + Locking Band
Inspection Tee (Rectangular)
125
22
15
15
15
10
22
1.5
12
12
3
3
4
4
6
4
1.5
22
15
22
100
22
15
15
15
10
22
1.5
12
12
3
3
4
4
6
4
1.5
22
15
22
150
18
15
15
15
10
18
1.5
12
12
3
3
4
4
6
4
1.5
18
10
18
180
18
15
15
15
10
18
1.5
12
12
3
3
4
4
6
4
1.5
18
10
18
200
18
15
15
15
10
18
1.5
12
12
3
3
4
4
6
4
1.5
18
10
18
33