26
Ignis-Protect
6.
Remove wood fibre board, thermal
insulation etc. from the assembly
opening.
7.
Install the wooden surround for
Ignis-Protect into the studwork.
1.
Clear installation width required
565mm.
2.
Clear installation height of 700mm on
90° version,1020mm on 45° version
for walls between 100 - 200mm
thick, and height 1320mm on walls
between 250 - 500mm thick.
Window and door lintels and
their support areas, as well as
other bearing elements must
not be weakened!
In case of uncertainty consult
a structural engineer.
IMPORTANT!
3.
Remove plasterboard.
NOTE: The vapour barrier must
not be damaged!
4.
Cut a cross shape in the vapour
barrier to the required dimensions
of the opening (see figs. 1. and 2.)
The dimensions of the
IGNIS-PROTECT wall bushings
have already been matched to
the standard centre-to-centre
dimensions of wooden
stud walls!
TIP:
Make the opening.
NOTE: Bearing
elements must not be weakened!
IMPORTANT: follow the safe
working notes on page 29.
5.