background image

1

6

0

0

09

 1

50

3 E

N

mod. Touch, I.T., Light

WAVE

Use

 &

 M

ain

te

na

nc

e M

an

ua

l

Summary of Contents for WAVE I.T.

Page 1: ...1 6 0 0 0 9 1 5 0 3 EN mod Touch I T Light WAVE Us e M a i n t e n a n c e M a n u a l...

Page 2: ......

Page 3: ...ON OF THE UNIT 9 DESCRIPTION OF THE TOUCH VOL AND I T VOL KEYPAD 13 FUNCTIONS OF THE VOLUMETRIC KEYPAD 14 FUNCTIONS OF THE TOUCH KEYPAD 16 FUNCTIONS OF THE LIGHT I T AND LIGHT KEYPADS 17 TECHNICAL FEA...

Page 4: ...URA product We have designed and manufactured this product with great care to ensure that it will dispense water of the highest quality In order to get the most out of your water cooler please read th...

Page 5: ...t should not be treated as domestic waste but should be taken to a dedicated recycling centre for electrical and electronic equipment Immediately prior to scrapping cut off the power cable For more in...

Page 6: ...inisterial Decrees 174 of 06 04 2004 and 25 of 07 02 2012 Electrical safety This water cooler is designed manufactured and marketed in compliance with the safety objectives of the Low Voltage Directiv...

Page 7: ...RDS 2015 ROME 2014 BEST PROMOTION OF HEALTH AND HYDRATION EUROPEAN AQUA AWARDS 2014 BUDAPEST 2013 BEST PRODUCT INNOVATION EUROPEAN AQUA AWARDS 2013 BERLIN 2012 BEST ENVIRONMENTALLY FRIENDLY PRACTICE E...

Page 8: ...e refrigerant circuit are not damaged The unit is not intended for use by children If the power cable is damaged it must be replaced by the manufacturer by its technical support service or by a qualif...

Page 9: ...ter Easily programmable water dosage system with volumetric control VOL model Glass touch screen controls easy to use and hygienic Self diagnosing system and alarm in case of lack of mains water lack...

Page 10: ...10 External Front View 1 3 4 5 6 7 2 5 6 7 2 3 4 1 Safety lock Removable Top Cover Touch control keypad Draft protection Front Door Drip Tray Grid Drip...

Page 11: ...2 3 4 1 General switch Adjustable thermostat Exit water solenoid valve Removable exit water pipe Ice bank inlet pipe joint 5 16 8 mm Inlet safety valve with check valve and mechanical filter 5 16 8 mm...

Page 12: ...12 Rear View 1 2 3 3 2 1 ENERGY SAVING button only I T VOL model IEC inlet power cord Support feet...

Page 13: ...ators RED led on the LEFT Little or no water at the inlet YELLOW led on the RIGHT Little or no CO2 remaining FIZZ model L 2 BLUE led STAND BY Quick flashing Little or no water at the inlet Slow flashi...

Page 14: ...stop the dispensing process at any time by pressing the button again SETTING THE QUANTITIES Thanks to the Volumetric dispensing functionality you can customize the pre set quantities dispensed by eac...

Page 15: ...ase the associated YELLOW LED turns itself on TOUCH VOL mod or the BLUE led L 2 starts to flash slowly I T VOL mod and all of the dispensers continue to work as normal ATTENTION on model WAVE FIZZ 30...

Page 16: ...plying there is a Beep sound and led are switch off STAND BY KEYPAD LOCK button P 4 A short push of the button activates the stand by function In this case the LEDs of all the dispensing buttons and t...

Page 17: ...FUNCTIONS SPARKLING WATER DISPENSER button P 1 ROOM TEMPERATURE WATER DISPENSER button P 2 COLD WATER DISPENSER button P 3 The water is dispensed while pressure is being applied to the button Function...

Page 18: ...18 Technical Features Technical Data Plate 10 Year of manufacture 10 Month of manufacture 00067 Serial number mod Wave...

Page 19: ...Dimensions WAVE 30 WAVE 60 WAVE 80 LxDxH mm 272x453x467 330x489x467 330x599x467 H L W PRP DAT FIRMA NOME FINITURA SE NON SPECIFICATO QUOTE IN MILLIMETRI FINITURA SUPERFICIE TOLLERANZE LINEARE ANGOLARE...

Page 20: ...t 7 lt 14 lt Ice bank 1 5 kg 3 5 kg 5 5 kg Supply Single phase 230V 50Hz Power 180 W 350 W 450 W Condensation Forced ventilation fan Refrigerant gas HFC R134a Natural gas HC R290 Working room temperat...

Page 21: ...that the watercooler has not been damaged during transport Any signs of damage must be reported to the Agent immediately If the watercooler has been transported in a horizontal or inclined position a...

Page 22: ...st 10 cm around the unit to allow for aeration Filling the Ice Bank Open the rear panel using the supplied key Fill the ice bank using the specific inlet pipe joint 5 16 8 mm 1 The ice bank is complet...

Page 23: ...wall tap The watercooler comes with a non return valve 2 and a security valve 3 It s not included a water pressure reducer that must be assembled before the WAVE Once the pipes are attached turn on th...

Page 24: ...witch 2 The compressor and fan are now activated On the FIZZ models press the Sparkling Water button on the right 4 in order to release any air in the circuit and to allow the pump to activate and fil...

Page 25: ...ders inside the unit To increase or decrease the level of carbonation of the water you need to adjust the screw 1 Turning it clockwise increases the level of carbonation We recommend that you do not e...

Page 26: ...r cylinders or surfaces dropping the cylinders or subjecting them to mechanical stress All of the above may compromise their integrity and resistance The cylinders must not be lifted by the cap or dra...

Page 27: ...s with dimensions of 0 5 microns and above It also reduces the levels of any contaminants such as asbestos fibres and micro organisms such as Cryptosporidium and Giardia It protects gaskets pumps tube...

Page 28: ...220V 50Hz Power 12Wh Maximum water flow 5 liters min Minimum pressure 0 5 bar Maximum pressure 9 bar Radiation 30 000 Ws cm2 Green LED ON bulb is on Maximum duration of the bulb 8 000 hours 11 months...

Page 29: ...d technical personnel who have completed specific training courses on hygiene and sanitization To sanitize the unit we recommend the use of hydrogen peroxide oxygenated water 5 diluted in drinking wat...

Page 30: ...so be washed in the dishwasher Cleaning the dispensing nozzles On a daily basis spray our SANIFICATION SPRAY code 190010 onto the nozzles Alternatively you can use a diluted hydrogen peroxide solution...

Page 31: ...31 Service history Installation Technician Date Notes Signature Maintenance Technician Date Notes Signature...

Page 32: ...e free of charge replacement of any parts that have been shown to have manufacturing defects The warranty does not include normal wear and tear to the components or any damage caused to the components...

Page 33: ......

Page 34: ......

Page 35: ...160009 Rev 01 23 04 2016 11 59...

Page 36: ...ura srl Registered office Via F lli Brancondi 56 60025 Loreto AN Italy Headquarters Via Erideo Marinucci 2 4 62019 Recanati MC Italy Tel 39 071 9710080 Fax 39 071 9710084 info blupura com www blupura...