Document #: BZ420-XXX
8
Electrical Installation
The Bluezone unit
is equipped with a 6’
power cord. The unit may be hardwired into
an AC junction box or plugged into an
appropriate AC receptacle.
Once the Model 420 is positioned
mechanically in the space, plug or wire the
unit into the nearest un-switched electrical
out
let rated to the voltage on the unit’s
model/serial number plate.
Secure the cord.
Warning
The power cord is attached to the front of
the unit and may be caught and pulled
during activities in the space. Secure the
power cord to the shelving, wall or other
stable surface, as close to the strain relief
as possible.
Electrical Requirements
Input Voltage: 90VAC
– 277VAC
Input Frequency: 50/60Hz
Input Current: 2.5A max @ 120VAC, 1.25A
max @ 240VAC
Input Power: 300W max
Installation for Pigtailed
Systems
Installation of an M420 with a pigtail power
cable involves wiring the system into a
permanent location such as an electrical
junction box. Ensure that all local safety
regulations are adhered to when installing
the M420.
Danger
Never install the M420 pigtail connection
until power is removed from the site of the
connection. This may involve local safety
procedures such as lock-out/tag-out, etc.
Refer to your local site safety administrator
before proceeding.
The M420 pigtail power cable wiring table is
shown below:
Table 2: M420 Pigtail Power Cable Wiring
Name
Color Identification
Line
Blue
Neutral
Brown
Ground
Green Stripe
Important
Only connect the M420 line/neutral
connections to an appropriate power source
(120VAC/240VAC, single phase, 50/60Hz,
able to supply at least 300W continuously).
Warning
Connecting to a power source other than
one specified above may result in
destruction of the M420 and may pose a
risk of injury. Only connect the system to an
appropriate power source.
Summary of Contents for Model 420
Page 4: ...Document BZ420 045 3 Key Components 2 6 3 5 4 1 ...
Page 8: ...Document BZ420 XXX 7 Figure 3 Illustration of the Ceiling Mount and Shelf Mount ...
Page 20: ...Document BZ420 XXX 19 Figure 10 Carefully Slide off Bulb Clips using Nitrile Gloves ...
Page 21: ...Document BZ420 XXX 20 Figure 11 Completed Bulb Assembly Figure 12 Bulb counter reset button ...
Page 28: ...Document BZ420 XXX 27 Figure 12 Completed Assembly ...
Page 30: ...Document BZ420 XXX 29 ...