Document #: BZ420-XXX
2
When conducting maintenance, power down
the unit and wait 15 minutes before removing
the cover.
There will be residual ozone inside the
Bluezone Model 420.
Do not breathe air directly from inside the
unit.
Description
The Bluezone® Model 420 is an air
purification device that eliminates airborne
contaminants including microbes (fungi, mold
and bacteria), odors and ethylene.
The Bluezone Model 420 is designed for use
in greenhouses or grow houses.
The Model 420 can be hung or mounted to
the ceiling or wall, or located on a shelf.
The Bluezone Model 420 draws in air
containing impurities that can lead to mold
development and eventually crop destruction,
and discharges air with a highly reduced
concentration of these impurities.
The facility, crop, and personnel have no
contact with the process that is cleaning the
air.
The unit is completely self-contained.
The Bluezone unit’s operation is controlled by
a microprocessor-based controller that
ensures safe operation at all times and alerts
the user to any system faults.
Specifications
The specifications of the Bluezone Model 420
are shown in Table 1.
Table 1: Bluezone Model 420
Specifications
Specification
Category
Model 420
Application
Grow facilities, dispensaries and
labs
Size
31” X 14” X 13.5”
79cm X 36 cm X 34 cm
Product Weight
25 lbs./11kg
Shipping Size
36” X 20” X 20”
91cm X 51cm X 51cm
Shipping Weight
28 lbs/13 kg
Operating
Environment
34°F
– 104°F
1C
– 40C
up to 90% RH
Storage
Environment
-4°F
– 150°F
-20C
– 65C
up to 90% RH
Treatment
volume
15,000 cubic feet
430 m
3
per Bluezone
Input Voltage
120 or 240 VAC 1 Phase
Current
3 amps (at 120VAC)
1.5 amps (at 240VAC)
Power
300 Watts
Electrical
Connection
Standard 120/240 VAC cord with
pig tail for direct wiring or plug on
request
Mounting
Options:
Hung from ceiling, placed on
shelf/rack/cart, or mounted to wall
Summary of Contents for Model 420
Page 4: ...Document BZ420 045 3 Key Components 2 6 3 5 4 1 ...
Page 8: ...Document BZ420 XXX 7 Figure 3 Illustration of the Ceiling Mount and Shelf Mount ...
Page 20: ...Document BZ420 XXX 19 Figure 10 Carefully Slide off Bulb Clips using Nitrile Gloves ...
Page 21: ...Document BZ420 XXX 20 Figure 11 Completed Bulb Assembly Figure 12 Bulb counter reset button ...
Page 28: ...Document BZ420 XXX 27 Figure 12 Completed Assembly ...
Page 30: ...Document BZ420 XXX 29 ...