Document #: BZ420-045
5
Installation
An overview of Mechanical and Electrical
Installation instructions is contained in this
section. Details of steps to hang the Model
420 from the ceiling or mount on a shelf are
contained in Appendix ***.
Installation Guidelines
Place the Model 420 in the room so that air
flow from the HVAC system, fans or other
air flow systems does not blow directly into
or pull air through the Model 420 air inlet or
clean air outlet.
If the Model 420 is installed with its air inlets
or clean air outlet directly in line with the
airflow from an HVAC outlet or fan, ensure a
minimum clearance instance
of 5’ (1.5 m) to
avoid excessive air flow through the unit.
Place the unit so that the control panel and
display are visible and accessible.
Each Model 420 has the capacity to purify
up to 15,000 cubic feet (430 m
3
) of space.
For spaces greater than 15,000 cubic feet
(430 m
3
), multiple Model 420 units will be
required.
If multiple Bluezone Model 420 units are
being installed in a room, the following are
recommended guidelines for the placement
of the Bluezone units:
1.
Distribute the units relatively evenly
throughout the space.
2.
Generally spreading the locations
across the available space is good
practice.
3.
Warning: Hang the units from the
ceiling, mount to the wall or on a
shelf/rack to avoid unintended bumping
of the units.
4.
Units hung from the ceiling should be
hung to the level of the lights, but not
below lights to avoid blocking light to
the plants.
5.
Warning: If the unit is located in an
area with foot traffic and there is a
concern that it could be bumped by
personnel, it should be labeled with
colored tape to make it more visible
and reduce the risk of collision.
6.
Warning: Locate the junction
boxes for the units as close as possible
to the units to avoid the risk of hooking
the cord and pulling it out. If the
distance to the junction box is more
than 2’ (0.6m), the cord should be tied
to the wall, rack, or ceiling to keep it
protected.
Summary of Contents for Model 420
Page 4: ...Document BZ420 045 3 Key Components 2 6 3 5 4 1 ...
Page 8: ...Document BZ420 XXX 7 Figure 3 Illustration of the Ceiling Mount and Shelf Mount ...
Page 20: ...Document BZ420 XXX 19 Figure 10 Carefully Slide off Bulb Clips using Nitrile Gloves ...
Page 21: ...Document BZ420 XXX 20 Figure 11 Completed Bulb Assembly Figure 12 Bulb counter reset button ...
Page 28: ...Document BZ420 XXX 27 Figure 12 Completed Assembly ...
Page 30: ...Document BZ420 XXX 29 ...