6.1.4 Gain
Able to set by each R,G,B,IR.
There is the setting box at
「
Gain
」
in the camera control tool.
4 windows, R(left), G(left middle), B(right middle), IR(right)
Gain setting range
:
512
~
6400
Ex)
:
0dB
:
1600,
12dB:6400, -3dB:512
Gain setting resolution: 1step= 1/1600
6.1.5 Black level
Able to set by each R,G,B,IR.
There is the setting box at
「
Black
」
in the camera control tool.
4 windows, R(left), G(left middle), B(right middle), IR(right)
Setting range
:
0
~
512
1
step=0.0625LSB
6.1.6 One push Auto White Balance
This mode has 2 options by Gain control and Exposure control.
In Exposure control, Trigger select must be ”Shutter select Mode”.
Detection area of white balance adjustment is in the center of 1024pixles out of 4096.
・
SHUTTER button is invalid in the other mode of
「
Trigger
」
and
「
Shutter select Mode
」
・
SHUTTER button is only valid in
「
Trigger
」「
Shutter select Mode
」
Gain cnotrol base of One push AWB
1) Select
「
User Set 1
」
or
「
User Set 2
」
in the pull down menu of
「
White Balance
」
.
2) Click
「
GAIN
」
, AWB is excuted.
「
SHUTTER
」
button is INVALID.
Exposure control base of One push AWB
1) Select
「
Shutter select Mode
」
in the pull down menu of
「
Trigger
」
.
2) Select
「
User Set 1
」
or
「
User Set 2
」
in the pull down menu of
「
White Balance
」
.
3) Click
「
SHUTTER
」
in Adjustment.
In this mode (Exposure control), Gain control base of AWB is also available.
AWB is executed by Exposure time control.
※Exposure time shuould be set within LinePeriod(us), in case of exposure time setting over the