5.2 Camera Link output Basic Timing chart
Note 1: LVAL low level period in the above drawing is clock number when the trigger mode
is OFF and the line period is the minimum value.
Note 2: The time of Pixel and clock is the same.
1CLK = 1PIXEL = 12.5ns
5.2.1 OB output mode “ON”, PixelRemap mode”OFF”
The drawing includes 16 pixels of optical black at the left and the right during LVAL Active period.
LVAL
R、G、B VIDEO
SWIR VIDEO
DVAL
Ch
①
②
③
④
⑤
Total CLK
R,G,B
1~4096 4096
4128
308
308
4436
SWIR
1~1024 1024
5.2.2 OB output mode “OFF”, PixelRemap”OFF”
It can be output Active Pixel of sensor in the period of LVAL Active.
Full resolution
LVAL
R、G、B VIDEO
SWIR VIDEO
DVAL
Ch
①
②
③
Total CLK
R,G,B
1~4096 4096
340
4436
SWIR
1~1024 1024
③
②
Optical Black
Optical Black
Active Pixel
①
④
16 Pixel
16 Pixel
②
Active Pixel
①
②
Pixel
Optica Black
16PIXEL
Optical Black
16PIXEL
Active Pixel
①
③
②
Active Pixel
①