OPERATING  INSTRUCTIONS

Airflow direction control

   Adjust the air flow direction properly otherwise it 
   might cause discomfort or  cause uneven room 
   temperatures.
   Adjust the horizontal/vertical louver using the remote 
   controller. For some models, the vertical louver can
   only be adjusted manually.

  

To set the horizontal/vertical air flow direction

   

Perform this function while the unit is in operation.

   Use the remote controller to adjust the air flow direction. 
   The vertical/horizontal louver changes 6 degree in angle
    for each press, or swing up and down automatically. 
    Please refer to the   REMOTE CONTROLLER OPERATION 
    MANUAL    for details. 
   

   

   

For some models, the vertical louver can only be adjusted
manually. Move the deflector rod  manually to adjust the air 
flow in the direction you prefer.

IMPORTANT

: Do not put your fingers into the panel of 

blower and suction side. 

The high-speed fan inside may 

cause danger.

    

Do not operate the air conditioner for long periods with 
the air flow direction set downward in cooling or 
dehumidifying mode. Otherwise, condensation may 
occur on the surface of the horizontal louver causing
 moisture to drop on to the floor or on furnishings.
When the air conditioner is started immediately after it 
was stopped, the horizontal louver might not move for 
approximately 10 seconds.
Open angle of the horizontal louver should not be set 
too small, as COOLING or HEATING performance may 
be  impaired due to too restricted air flow area.
Do not move the horizontal louver manually, otherwise
 the horizontal louver will be out of sync. Please cease 
operating, unplug power for a few seconds,then restart 
the air conditioner.
Do not operate unit with horizontal louver in closed 
position.

CAUTION

,,

,,

OPERATING  INSTRUCTIONS

NOTE: This manual does not include Remote Controller Operations, see the 
<<Remote Controller Instruction>> packed with the unit for details. 

Deflector rod

Range

Range

AUTO/COOL

Suspension bars

AUTO/COOL

(1)

(2)

Manual operation

Operating temperature

Manual switch

Manual switch

Open and lift the front panel up to an angle 
until it remains fixed  with a clicking sound. 
For some models, please use suspension
bars to prop up the panel.

lead to the forced AUTO operation. If press
the switch twice within five seconds, the unit
will operate under forced COOL operation.
Close the panel firmly to its original 
position.

One press of the manual control switch will 

This switch is used for testing purposes 
only. You had better not choose it.
To restore the remote controller operation, 
use the remote controller directly.

CAUTION:

1

3

2

NOTE:

 The unit must be turned off before

operating the manual control button. If the 
unit is operational, continue pressing the 
manual control button until the unit is off.

Units are equipped with a switch to run emergency operation mode. It can be accessed by 
opening the front panel. This switch is used for manual operation in case the remote controller
fails to work or maintenance necessary.

Mode

Temperature
Room temperature

Outdoor temperature

1. Optimum performance will be achieved within these operating temperatures. If air 
    conditioner is used outside of the above conditions, certain safety protection features 
    might come into operation and cause the unit  to function abnormally.
2. If the air conditioner runs for a long time in cooling mode and the humidity is high(over 
    80%) , condensed water may drip out of the unit. Please sets the vertical air flow louver to
    its maximum angle (vertically to the floor), and set HIGH fan mode.

Suggestion: 

 For the unit adopts an Electric Heater, when the outside ambient  temperature

O

O

 is below 0 C(32 F), we strongly recommend you to keep the machine plugged in order to 
guarantee it running smoothly.

NOTE:

Cooling operation

Heating operation Drying operation

  

For the models with low 

    temperature cooling system)

O

O

O

O

(-15 C~50 C/5 F~122 F:

O

O

17 C~32 C

O

O

(62 F~90 F)

O

O

0 C~30 C

O

O

(32 F~86 F)

O

O

0 C~50 C

O

O

(32 F~122 F)

O

O

0 C~50 C

O

O

(32 F~122 F)

O

O

-15 C~30 C

O

O

(5 F~86 F)

O

O

10 C~32 C

O

O

(50 F~90 F)

Summary of Contents for BM09Y18

Page 1: ...anual where the operator can easily find them Inside you will find many helpful hints on how to use and maintain your air conditioner properly Just a little preventative care on your part can save you...

Page 2: ...the European countries please read the following information This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lac...

Page 3: ...the air conditioner in places where combustible gas can be emitted Emitted gas may collect and cause an explosion Never allow the air conditioner to run for too long with the doors or windows open or...

Page 4: ...r under Cooling operation for about half an hour Once the Self Clean function is activated all TIMER setting will be cancelled During Self Clean operation when press the SELF CLEAN button on the remot...

Page 5: ...O COOL Suspension bars AUTO COOL 1 2 Manual operation Operating temperature Manual switch Manual switch Open and lift the front panel up to an angle until it remains fixed with a clicking sound For so...

Page 6: ...op running Clean the air filter periodically otherwise cooling or heating performance may be reduced Do not operate unit with horizontal louvre in closed position The fan speed will be automatically c...

Page 7: ...ssor can t restart for 3 4 minutes after it stops Anti cold air Cooling and heating models only The unit is designed not to blow cold air on HEAT mode when the indoor heat exchanger is in one of the f...

Page 8: ...ormally Trouble OPERATION indicator or other indicators continue flashing If one of the following code appears on the display area E0 E1 E2 E3 or P0 P1 P2 P3 TROUBLESHOOTING TIPS Troubleshooting guide...

Page 9: ......

Reviews: