background image

 

 

Bluegiga Technologies Oy 

Page 7 of 20 

1.1  PIO Connections in the Carriers 

FUNCTION 

BLE112 

BLE113 

BLE121LR 

UART CTS 

P0_2 

UART RTS 

P0_3 

UART TX 

P0_4 

UART RX 

P0_5 

SPI CLK 

P1_3 

SPI MISO 

P1_4 

SPI MOSI 

P1_5 

DISPLAY CS 

P1_6 

FLASH CS 

P0_7 

(pulled down in the 

carrier) 

ACCELEROMETER CS 

P1_2 

DISPLAY RS / FLASH SUPPLY 

P1_1 

P0_7 

DCDC CNTRL 

P1_7 

DCDC_CNTRL (* 

LED / USB PU 

P1_0 

POTENTIOMETER 

P0_6 

BUTTON1 

P0_0 

BUTTON2 

P0_1 

BUTTON3 

P2_0 

*) Connect using a shorting link in the carrier 

Table 1: PIO connections in the carriers 

 

1.2  Important Notes about the Differences between the Module Carriers 

In  BLE121LR  the  PIOs  P1_0  and  P1_1  are  reserved  for  the  internal  front  end  control  of  the  module.  Also 
P1_7 is reserved for this purpose and in case of BLE121LR it can only  be used as an output controlling the 
external DCDC. Thus in BLE121LR P1_7 is named as DCDC CNTRL. 

 The important differences between the carriers are shown in the Figure 4 (BLE112 and BLE113 carriers) and 
Figure 5 (BLE121LR carrier). 

Summary of Contents for DKBLE

Page 1: ...DKBLE USER GUIDE Monday 19 May 2014 Version 1 0...

Page 2: ...r specifications detailed here at any time without notice and does not make any commitment to update the information contained here Bluegiga s products are not authorized for use as critical component...

Page 3: ...Bluegiga Technologies Oy VERSION HISTORY Version Comment 1 0 First published version...

Page 4: ...R Carrier 9 1 2 2 Minimizing the Current Consumption 9 1 3 Sensors display and USB to UART converter 9 2 Getting Started With DKBLE 10 2 1 Using the On Board Debugger to Program the Carriers 10 2 2 Us...

Page 5: ...ery or USB UART interface through USB to UART converter USB interface programming interface for upgrading the firmware and parameters Display connected to SPI Accelerometer connected to SPI Altimeter...

Page 6: ...een of the module carrier Output of the on board cc debugger To program an external BLExxx device connect the debug interface of the device here To program the module carrier switch to MODULE To progr...

Page 7: ...P0_0 BUTTON2 P0_1 BUTTON3 P2_0 Connect using a shorting link in the carrier Table 1 PIO connections in the carriers 1 2 Important Notes about the Differences between the Module Carriers In BLE121LR th...

Page 8: ...VDD CS BLE121LR CARRIER 100k R3 SPI MISO P1_4 P0_7 Figure 4 Connections in BLE112 and BLE113 Carriers 100k R3 P0_7 100k R2 2V 3V3 Not Connected 1 5k R6 USB 200R R32 2V 3V3 DISPLAY RS FLASH VDD CS Not...

Page 9: ...ternal pull down resistor For this reason port P1 can t be configured to have internal pull ups the default setting of the module but the port P1 must be pulled low in the HW configuration file In BLE...

Page 10: ...er successful installation the tools can be found from the start menu Figure 6 Bluegiga tools and examples in the Windows start menu 2 1 Using the On Board Debugger to Program the Carriers To program...

Page 11: ...alog comparator of BLE112 BLE113 and BLE121LR is fixed to the pins P0_4 and P0_5 The pins overlap with the UART TX and RX signals in DKBLE Thus to use the analog comparator the USB to UART converter m...

Page 12: ...cted If USB is not connected then the instrumentation amplifier must be turned off and by passed using the switch labeled CURRENT MEAS OFF ON to avoid excessive leakage current into the input of the a...

Page 13: ...illoscope Coupling DC Vertical scale 500 mV DIV Horizontal scale 200 s DIV Level 2 5 V Offset 2 0 V Trigger Normal falling edge The instrumentation amplifier inverts the signal The current consumption...

Page 14: ...Bluegiga Technologies Oy Page 14 of 20 4 Schematics and Assembly Drawing Figure 12 BLE113 Evaluation Board Schematic 1 6...

Page 15: ...Bluegiga Technologies Oy Page 15 of 20 Figure 13 BLE113 Evaluation Board Schematic 2 6...

Page 16: ...Bluegiga Technologies Oy Page 16 of 20 Figure 14 BLE113 Development Board Schematic 3 6...

Page 17: ...Bluegiga Technologies Oy Page 17 of 20 Figure 15 BLE113 Development Board Schematic 4 6...

Page 18: ...Bluegiga Technologies Oy Page 18 of 20 Figure 16 BLE113 Development Board Schematic 5 6...

Page 19: ...Bluegiga Technologies Oy Page 19 of 20 Figure 17 BLE113 Development Board Schematic 6 6...

Page 20: ...s sales bluegiga com Technical Support www bluegiga com support Orders orders bluegiga com WWW www bluegiga com Head Office Finland Phone 358 9 4355 060 Fax 358 9 4355 0660 Sinikalliontie 5A 02630 ESP...

Page 21: ...Mouser Electronics Authorized Distributor Click to View Pricing Inventory Delivery Lifecycle Information Bluegiga Technologies DKBLE...

Reviews: