GB
GOOD
TO
KNOW
BEFORE
USE
Gas
type:
I3B
/
P
(30)
Nominal
pressure:
28
‐
30mBar
piezo
ignition
Voltage:
220
‐
240V
‐
50Hz
Overheat
protection:
thermostat
Fuel:
LPG
Max
power
LPG:
4.2
kW
‐
300gr
/
t
Med
power
LPG:
2.7
kW
‐
200
g
/
t
Min
power
PLG:
1.4
kW
‐
100gr
/
t
Maximum
power
heating:
2
kW
Minimum
power
heating:
1kW
Fan:
20W
SAFETY
Thermoelectric
protection
Atmosphere
analyzer
Piezo
ignition
INSTALLATION
AND
USE
Always
use
an
approved
regulator
and
hose
Place
on
a
flat
surface
Do
not
use
the
heater
in
the
bedroom,
bathroom
or
permanent
heating.
It
is
not
approved
for
use
in
public
buildings,
schools,
halls,
community,
housing,
hospitals
and
nursing
homes,
nursing
homes,
schools,
showrooms,
warehouses,
etc.
Do
not
use
in
a
basement
or
below
soil
surface..
•
Do
not
place
the
heater
under
or
near
electrical
installations.
Safety
distance
to
the
nearest
object
is
60
cm,
both
forwards,
sides
and
top.Do
not
use
in
rooms
less
than
84m3
at
max,
56m3
on
medium
mode
and
28m3
on
min
mode.
Please
see
chart
below.
Gas
stoves
may
be
used
only
in
dry
areas,
and
may
not
be
used
inside
of
caravans
or
similar
Do
not
place
the
unit
near
other
heat
sources
Do
not
place
in
premises
where
there
is
already
a
gas
bottle
Use
only
in
well
‐
ventilated
room
and
not
in
areas
with
flammable
gases
or
flames
The
device
must
not
be
used
without
supervision
The
appliance
is
not
intended
for
use
by
persons
(including
children)
with
reduced
physical,
sensory
or
mental
capabilities,
or
lack
of
experience
and
knowledge,
unless
thay
have
been
given
supervision
or
instruction
concerning
use
of
the
appliance
by
a
person
responsible
for
their
safety.
Children
should
be
supervised
to
ensure
that
they
do
not
play
with
the
appliance.
If
the
supply
cord
is
damaged,
it
shall
be
replaced
by
the
manufacturer,
its
service
agent
or
similarly
qualified
persons
in
order
to
avoid
a
hazard.
Do
not
cover
the
heater
Do
not
move
the
heater
while
it
is
operating
Do
not
place
the
heater
near
flammable
material
In
case
of
gas
‐
immediately
turn
off
gas
cylinder
valve.
Do
not
light
bulbs
or
flames.
Open
doors
and
windows.
Have
the
stove
checked.
Ensure
that
legal
and
approved
LPG
is
used
Check
hose
and
regulator
regularly
The
appliance
should
not
be
used
during
soil
surface
or
ground
INSTALL
GASREGULATOR
AND
GAS
BOTTLE
Screw
the
hose
to
the
stove
and
regulator
and
tighten
the
hose
clamp
Only
use
approved
regulator.
Screw
the
regulator
onto
the
tank
crane
Place
the
cylinder
in
the
space
Attach
the
back
cover
on
the
gas
stove
Open
the
tap
counterclockwise.
Make
sure
there
are
no
leaks.
Use
soap
for
this
purpose
(1
part
soap
to
1
part
water).
NEVER
use
free
flames.
STARTING
GAS
HEATING
Follow
the
"INSTALLATION
AND
USE"
and
place
the
gas
stove
in
the
desired
location
Open
the
valve
on
the
LPG
bottle
counterclockwise
Press
down
on
the
knob
and
hold
it
pressed.
Press
the
piezo
button
repeatedly
until
the
pilot
and
some
of
the
burners
lit
Keep
the
knob
pressed
for
a
further
20
‐
30
seconds
To
regulate
the
temperature,
press
down
the
knob
slightly
and
rotate
to
the
desired
position
Do
not
move
the
heater
when
it
is
hot
TURN
OFF
GAS
STOVE
AND
CYLINDER
Set
the
heaters
knobs
in
the
initial
position
by
turning
it
clockwise
to
position
1
Note
that
the
valve
on
the
gas
cylinder
must
be
closed
completely
by
turning
it
clockwise
until
the
tap
is
fully
closed.
The
pilot
flame
goes
out
USE
OF
FAN
AND
ELECTRIC
HEATING
Plug
the
cord
into
an
electrical
outlet
and
turn
on
the
fan
(heater
must
only
be
used
with
220
‐
240V)
When
the
fan
is
on,
you
can
turn
on
the
electric
heat
in
two
steps:
mode
I
which
is
rated
at
1000W
and
mode
II
also
turned
on
the
effect
2000W
Shutdown,
simply
turn
the
two
switches
for
heat
and
then
turn
off
the
fan
TROUBLESHOOTING
Burner
does
not
light
up
‐
bad
gas
inlet,
the
controller
does
not
work,
check
for
gas
in
the
bottle
The
burner
has
misfire
or
turns
off
‐
check
for
gas
in
the
gas
bottle,
check
the
hose
connections,
consult
sales
store
or
supplier
Unstable
flames
‐
replace
bottle,
contact
sales
store
or
supplier
Pilot
flame
does
not
light
up
‐
clogged
pilot
light.
Contact
sales
store
or
supplier
If
the
electric
fan
does
not
work
‐
check
the
fuse
(glass
fuse
10A).
Make
sure
the
gas
stove
is
off
and
cool,
and
that
the
power
cord
is
unplugged.
Inside
the
stove
top
left
hand
corner
there
is
a
black
fuse
holder
is
opened
by
turning
counterclockwise.
Check
the
fuse
and
replace
if
necessary.
Screw
the
fuse
holder
and
plug
in
the
power
cord
and
check.
If
the
fan
is
not
working
now
so
please
contact
sales
store,
or
supplier.
REMOVE
GAS
REGULATOR
AND
REPLACING
GAS
BOTTLE
Close
the
valve
on
the
gas
bottle.
Never
change
the
gas
cylinder
close
to
flames
or
other
flammable
fluids.
Remove
the
gas
cylinder
without
damaging
the
flexible
hose.
Unscrew
the
regulator
clockwise.
Make
sure
the
controller
connections
are
not
damaged.
Set
gas
cylinder
collected
in
a
safe
place.
MAINTENANCE
AND
CLEANING
Do
not
clean
the
stove
when
it
is
used
or
is
hot.
Use
a
soft,
dry
cloth
Check
the
rubber
hose
periodically
and
replace
if
necessary.
(mount
not
excessively
long
or
short
tubes,
50cm
is
enough
and
the
right
length).
Any
repairs
must
be
performed
by
authorized
personnel
using
original
spare
parts.
INSTRUCTIONS
FOR
STORAGE
When
the
season
is
over,
you
should
set
aside
the
stove
in
a
dry
place
and
cover
it
to
prevent
the
dust
on
and
in
the
burner.
WARRANTY
The
warranty
is
valid
for
two
years
in
the
following
form:
The
warranty
start
from
the
day
of
delivery,
the
purchase
certificate
invoice,
delivery
note
or
cash
receipt.
During
the
warranty
period
all
original
defective
parts
are
replaced
without
charge
for
materials
and
labor
costs.
Examination
of
warranty
accrues
only
manufacturer.
The
warranty
does
not
apply
to
regulator,
hose,
locking
ring
and
the
parts
with
defects
occurring
due
to
improper
operation,
maintenance
or
storage.
The
user
is
in
any
event
responsible
for
any
transportation
costs.
ENVIRONMENT
Protect
the
environment.
Your
appliance
contains
valuable
materials
which
can
be
reused
or
recycled.
Leave
it
to
a
recycling
center
when
it
is
exhausted.
MINIMUM
ROOM
SIZE
ANDVENTILATION
Level
A *
B *
1,4 kW
28 m
3
32 cm
2
2,8 kW
56 m
3
66 cm
2
4,2 kW
84 m
3
99 cm
2
*A
=Room
size
minimum
cubic
meters
*B
=
Room
ventilation
minimum
square
meters
TECHNICAL
SERVICE
If
you
require
technical
support,
please
contact:
Scandy
Garden
AB,
Box
9188,
200
39
Malmö,
Sweden
Tel:+4640214000,
e
‐
majl:[email protected],
www.scandygarden.eu