v1.7 - Jun 2019
6 |
P a g e
outputFrequency (default = 1). Sets the frequency of output sentences from the BlueFlyVario. The
BlueFlyVario hardware runs on a 20ms cycle (50 cycles per second). If outputFrequency is set to 1
then the hardware will send a sentence on each cycle. If set to 2 it will send a sentence every second
cycle and so on (if set to 50 is will send a sentence every 50th cycle, i.e. once per second). You might
use this with the LK8EX1 output mode to send a sentence five times per second (set to 10).
outputQNH (default = 101325). See outputMode = 2 above.