6.
Remove the silicone shock-absorption pad from the inside wall of the battery
compartment. (Be sure to replace it after the completion of this process.)
7.
Create a circuit between the round metallic contact on the bottom of the compartment
and the compartment wall for approximately 2-5 seconds.
8.
Replace the silicone shock-absorption pad, the battery, and the battery cap. If the reader
makes a long beeping sound with LED flashing, it means the reader is resetting itself.
Please wait for one minute then test to see if the reader is working. If it is working
normally, please calibrate its time using the software before further usage.
9.
Use the pliers to install the battery cover. Please note the notch on the inside tubing of the
reader. The battery cover should go down to a same or lower level than the bottom of the
notch.
Notch
15