background image

BP-2012S Data Sheet                                                      

     

Card-Reading 

Inductive / Non-Contact 

Card Format 

125 Khz EMID 

Maximum 

Reading Range 

(BlueCard Tags)

 

Model

 

Size

 

Range

 

BLC-02 

86mm×54mm 

6.0cm 

BLC-40 

Φ

40mm 

4.0cm 

BLC-30 

Φ

30mm 

3.5cm 

BLC-22 

Φ

22mm 

3.5cm 

BLC-6-28 

Φ

6mm×28mm 

3cm 

Power Capacity 

>330,000 Readings   

Battery Type 

CR123A 3v Single-Use Lithium 

Display 

LED Status light 

Shock 

Absorbency 

External: metal tubing, rubber shell. Internal: 

silicone gel padding, epoxy resin. Tested to 

withstand drops from 2 m (cement floor) 

Waterproofing 

Completely Sealed 

Memory 

30,719 Records 

Data Reliability 

Flash Memory, Stores Data Without 

Electricity 

PC Connection 

Wireless Comm Station 

Working Temp. 

-40

°

C to 70

°

Working Hum. 

0 to 95% 

Dimensions 

120mm×35mm×26mm 

Weight

 

                142g±5g 

 
BP-2012F Data Sheet                                                     

        

Card-Reading 

Inductive / Non-Contact 

Card Format 

125 Khz EMID 

Maximum 

Reading Range 

(BlueCard Tags)

 

Model 

Size 

Range 

BLC-02 

86mm×54mm  6.0cm 

BLC-40 

Φ40mm 

4.0cm 

BLC-30 

Φ30mm 

3.5cm 

BLC-22 

Φ22mm 

3.5cm 

BLC-6-28 

Φ6mm×28mm  3cm 

Power Capacity 

>330,000 Readings   

Battery Type 

CR123A 3v Single-Use Lithium 

Display 

LCD display, LED Status light 

Shock 

Absorbency 

External: metal tubing, rubber shell. Internal: 

silicone gel padding, epoxy resin. Tested to 

withstand drops from 2 m (cement floor) 

Waterproofing 

Completely Sealed 

Memory 

30,719 Records 

Data Reliability 

Flash Memory, Stores Data Without 

Electricity 

PC Connection 

Wireless Comm Station 

Working Temp. 

-20°C to 70°C 

Working Hum. 

0 to 95% 

Dimensions 

140mm×42mm×30mm 

Weight

 

                172g±5g   

 

11 

Summary of Contents for BP-2012F

Page 1: ...Inductive Guard Tour Reader Usage Manual BP 2012S Guard Tour Reader BP 2012F Guard Tour Reader Please read this manual carefully before starting to operate the reader ENGLISH...

Page 2: ...n at set points such as route guard location time and events then upload them to the PC for processing and verification The main different between BP 2012S and BP 2012F is the BP 2012F has a LCD displ...

Page 3: ...ing On and Off The system will turn on automatically to perform card reading when it is within the range of a valid signal card It will automatically shut off when card reading is complete Reading Car...

Page 4: ...be connected with the computer have its data uploaded then initialized BP 2012F A display of the current time If a card reading has just been made is accompanied by 4 beeps with 4 flashes of the LED...

Page 5: ...head of the BP 2012S BP 2012F should be between the status lights of the BS 1000 and its top should be flush against the inside edge of the BS 1000 The Connect window should be started in the PC softw...

Page 6: ...2012F guard tour reader in its indentation The reading head of the BP 2012S BP 2012F should be between the status lights of the BS 3300 and its top should be flush against the inside edge of the BS 33...

Page 7: ...Card Reader The BP 2012S BP 2012F guard tour reader can be used as a standard signal card reader used for various applications Troubleshooting After reading a card 1 beep with 4 flashings followed by...

Page 8: ...PC Solution 1 check to see if the PC software is opening properly and whether it is set up to communicate with the BP 2012S BP 2012F Solution 2 make sure that the BS 1000 wireless communication statio...

Page 9: ...process When you are uploading the records from BP 20002S or BP 2012F reader into software via BS 1000 please keep rest of the BP 2012S BP 2012F readers and EM Cards at lest one foot away from the BS...

Page 10: ...012F via BS 2000 BS 3000 BS 3000M BS 4000 BS 4000M and BS 6000 also please keep rest of the BP 2012S BP 2012F readers and EM Cards at lest one foot away from the stations Please contact with the techn...

Page 11: ...tion Working Temp 40 C to 70 C Working Hum 0 to 95 Dimensions 120mm 35mm 26mm Weight 142g 5g BP 2012F Data Sheet Card Reading Inductive Non Contact Card Format 125 Khz EMID Maximum Reading Range BlueC...

Page 12: ...cards NOT ALL BATTERIES ARE CREATED EQUAL Battery life depends significantly on age usage conditions type and brand DANGER Keep the battery pack away from fire or it might explode Do not expose it to...

Page 13: ...which can be purchased in many convenience stores Below is an example of the battery NOTE 2 BP 2012F use the exactly same way to change the battery Please follow the instructions to replace the BP 201...

Page 14: ...ring If the ring is damaged during the battery replacement process please replace it with the spares provided In addition please note that the cathode negative end of the battery is facing outwards S...

Page 15: ...e shock absorption pad the battery and the battery cap If the reader makes a long beeping sound with LED flashing it means the reader is resetting itself Please wait for one minute then test to see if...

Page 16: ...uding interference that may cause undesired operation Important Any Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate t...

Page 17: ...SAR Exemption Statement This device measured RF output power is less than the SAR exclusion threshold value for human head and body Therefore SAR test is not necessary Bluecard Technologies Corp 17...

Reviews: