![Blue-White FLEXFLO M4 Series Operating Manual Download Page 21](http://html1.mh-extra.com/html/blue-white/flexflo-m4-series/flexflo-m4-series_operating-manual_2776992021.webp)
To Enable 4-20mA Input:
1
Open the
App Drawer
2
Select
4-20mA Input
3
Select
Settings
to adjust
4-20mA input values
4
Confirm by selecting
Save
5
Select
Start
to enable 4-20mA
Input
8.2
4-20mA Input
This input mode allows the user to set a range of mA input signals to a given motor speed, flow
rate or rpm. Used to remotely control the pump with an incoming 4-20mA signal.
Four points on the slope must be defined:
1) a low mA value
2) an output rate at the low mA value
3) a high mA value
4) an output rate at the high mA value
Default settings:
4mA = 0% motor speed
20mA = 100% motor speed
Option: Stop the pump and select the graph icon to easily adjust sliders to desired settings
Confirm by pressing “Save”
Page 21
®
FLEXFLO M4
8.0
Input Setup
To Enable Manual Speed Adjust:
1
Open the
App Drawer
2
Select
Manual Speed Adust
3
Select
Start
to enable Manual
Speed
4
Tap on the feed rate to cycle
through to the option you want
to manually adjust
!
Percent motor speed
!
RPM
!
Flow rate
5
Adjust manual speed by
selecting
Increase
or
Decrease
8.1
Manual Speed Adjust
This input mode allows the user to set a specific speed and the pump will run at that speed
until stopped. There are up and down arrows on the home screen to incrementally adjust the
speed of the motor.
Default:
Percent motor speed.
Also Available:
Percent motor speed
RPM
Flow rate
Option: Stop pump and select settings to input desired motor speed.