WARRANTY

9.1 

Limited Warranty

Your Blue-White product is a quality product and is warranted for a specific time from date of purchase (proof of purchase is required). 
The product will be repaired or replaced at our discretion. Failure must have occurred due to defect in material or workmanship and not 
as a result of operation of the product other than in normal operation as defined in the product manual. Warranty status is determined 
by the product's serial label and the sales invoice or receipt. The serial label must be on the product and legible. The warranty status of 
the product will be verified by Blue-White or a factory authorized service center. 
CHEM-FEED® MD3 pumps are warranted for 5 years from date of purchase (proof of purchase is required). Pumps will be repaired or 
replaced at our discretion. 

9.2 

DIAFLEX  Warranty

®

DIAFLEX® diaphragms are warranted for the life of the pump. Blue-White will replace a damaged diaphragm at no cost to the customer 
provided the pump was at all times operated within the guidelines included in the pump's operation manual. This warranty only applies 
to DIAFLEX® diaphragms, not the pumps themselves. Blue-White pumps are separately covered by warranties specific to them.

9.3 

What is not Covered

>

    Flex-A-Prene diaphragm and rubber components - They are perishable and require periodic replacement

>

    Pump removal, or re-installation, and any related labor charge.

>

    Freight to the factory, or service center

>

    Pumps that have been tampered with, or in pieces.

>

    Damage to the pump that results from misuse, carelessness (such as chemical spills on the  

 

                

   

 

 enclosure), abuse, lack of maintenance, or alteration that is out of Blue-White control.

>

    Pumps damaged by faulty wiring, power surges, or acts of nature.

Blue-White does not assume responsibility for any loss, damage, or expense directly or indirectly related to or arising out of the use of 
its products.  Failure must have occurred due to defect in material or workmanship and not as a result of operation of the product other 
than in normal operation as defined in the pump operation manual.

The warranty status is determined by the pump's serial label and the sales invoice or receipt.  The serial label must be on the pump and 
be legible.  The warranty status of the pump will be verified by Blue-White or a factory authorized service center.

9.4 

Procedure for In-Warranty Repair

Warranty service must be performed by the factory or an authorized service center. Contact the factory or local repair center to obtain a 

RMA (Return Material Authorization) number. It is recommended to include foot strainer and injection/check valve fitting since these 
devices may be clogged and part of the problem. Decontaminate, dry, and carefully pack the product to be repaired. Please enclose a 
brief description of the problem and proof of purchase. Prepay all shipping and insurance cost. COD shipments will not be accepted. 
Damage caused by improper packaging is the responsibility of the sender. When In-Warranty repair is completed, the factory pays for 
return shipping to the dealer or customer.

9.5 

Product Use Warning

Blue-White products are manufactured to meet the highest quality standards in the industry. Each product instruction manual includes a 
description of the associated product warranty and provides the user with important safety information. Purchasers, installers, and 
operators of Blue-White products should take the time to inform themselves about the safe operation of these products. In addition, 
Customers are expected to do their own due diligence regarding which products and materials are best suited for their intended 
applications. Blue-White is pleased to assist in this effort but does not guarantee the suitability of any particular product for any specific 
application as Blue-White does not have the same degree of familiarity with the application that the customer/end user has. While Blue-
White will honor all of its product warranties according to their terms and conditions, Blue-White shall only be obligated to repair or 
replace its defective parts or products in accordance with the associated product warranties.

 BLUE-WHITE SHALL NOT BE LIABLE 

EITHER IN TORT OR IN CONTRACT FOR ANY LOSS OR DAMAGE WHETHER DIRECT, INDIRECT, INCIDENTAL, OR 
CONSEQUENTIAL, ARISING OUT OF OR RELATED TO THE FAILURE OF ANY OF ITS PARTS OR PRODUCTS OR OF THEIR 
NONSUITABILITY FOR A GIVEN PURPOSE OR APPLICATION.

9.6 

Chemical Resistance Warning

Blue-White offers a wide variety of wetted parts. Purchasers, installers, and operators of Blue-White products must be well informed 
and aware of the precautions to be taken when injecting or measuring various chemicals, especially those considered to be irritants, 
contaminants or hazardous. Customers are expected to do their own due diligence regarding which products and materials are best 
suited for their applications, particularly as it may relate to the potential effects of certain chemicals on Blue-White products and the 
potential for adverse chemical interactions. 

Blue-White tests its products with water only. The chemical resistance information included in this instruction manual was supplied to 
Blue-White by reputable sources, but Blue-White is not able to vouch for the accuracy or completeness thereof.  While Blue-White will 
honor all of its product warranties according to their terms and conditions, Blue-White shall only be obligated to repair or replace its 
defective parts or products in accordance with the associated product warranties.

 

BLUE-WHITE SHALL NOT BE LIABLE EITHER IN TORT OR IN CONTRACT FOR ANY LOSS OR DAMAGE, WHETHER DIRECT, 
INDIRECT, INCIDENTAL, OR CONSEQUENTIAL, ARISING OUT OF OR RELATED TO THE USE OF CHEMICALS IN 
CONNECTION WITH ANY BLUE-WHITE PRODUCTS.

CHEM-FEED

®

 Model Number

MD3

CHEM-FEED

® 

Multi-Diaphragm Metering Pump

Input Voltage / Power Cord

4

115V / 60Hz, power cord NEMA 5/15 plug (US)

5

230V / 60Hz, power cord NEMA 6/15 plug (US)

6

220V / 50HZ, power cord CEE 7/VII plug (EU)

8

240V / 50HZ, power cord AS 3112 plug (Australia/New Zealand)

9

230V / 50HZ, power cord BS 1363/A plug (United Kingdom)

X

No Power Cord

Elastomer Material (O-Rings)

V

TFE/P

E

EP

Miscellaneous Options 

(leave blank for standard model)

A

Hastelloy C check valve balls, standard injection fittings

H

PTFE balls (double ball check valve, prime valve, injection fitting) low 
viscosity/density fluids only

S

Flex-A-Prene

®

 Diaphragms (Caustic Soda resistant diaphragms)

MD3

2

4

4

X

V

X

-

S

Sample Model Number

Page 38

Page 39

®

CHEM-FEED  MD3

®

CHEM-FEED  MD3

Summary of Contents for CHEM-FEED MD3 Series

Page 1: ...Diaphragm Metering Pump Series MD3 CHEM FEED...

Page 2: ...3 1 Manual Adjust manual speed adjust 16 4 3 2 4 20 mA Input 17 4 3 3 0 10 VDC Input 18 4 3 4 Frequency Input Hz 19 4 3 5 Pulse Batch low speed batch 20 4 3 6 Manual Cycle Adjust repeating cycle time...

Page 3: ...m Model Number Matrix READ THE INSTRUCTION MANUAL PRIOR TO INSTALLATION AND USE 1 714 893 8529 sales blue white com customerservice blue white com 5300 Business Drive Huntington Beach CA 92649 Page 3...

Page 4: ...115V60Hz NEMA 5 15 USA 230V60Hz NEMA 6 15 USA 220V50Hz CEE 7 VII EU 240V50Hz AS 3112 Australia New Zealand Pump Head Assembly Pump Head PVDF Manifold PVDF Adapter Connections PVDF Valve Cartridges PVD...

Page 5: ...ite s output Flow Verification Sensor FVS system Includes stainless steel extended mounting brackets Lifts pump 4 1 2 11 43 cm for easy access in hard to reach areas Enclosure Rating NEMA 4X Construct...

Page 6: ...n check valve at discharge side of pump to prevent system fluid from flowing back through pump during pump maintenance A pressure relief valve is recommended at discharge of pump Bolt pump to a stable...

Page 7: ...0cm 4 00in 10 15cm n Made out of tough Stainless Steel n Provides a stable mounting surface Stainless Steel extended brackets allow the pump to be securely mounted to most any surface floor shelf or s...

Page 8: ...d and sealed Never strap control input output cables and power cables together Power Interruption This pump has a user programmable auto restart feature which will either restore the pump to the opera...

Page 9: ...AMP MAX AT 125 VOLT AC 0 8 AMP MAX AT 30 VOLT DC 5A SLOW BLOW 20 X 5MM 1 2 3 T1 PULSE GND 4 20 1 2 3 T1 PULSE GND 4 20 0 10 15VDC 1 2 T2 0 1000 HZ MAX NEGATIVE POSITIVE POSITIVE NEGATIVE NO VOLTAGE 96...

Page 10: ...elect menu items increase menu values by one and increase pump output in Manual Speed Adjust mode Press and hold to increase values progressively faster Press and release to stop the pump Press and re...

Page 11: ...e While making a selection where only one choice is allowed you will see a radio button Radio button example In a screen where you are making changes you will see the word Done located at the bottom o...

Page 12: ...e menu structure and enter the run mode Configuration Display Language Set Password Display Rate Esc Reset to Default Display Language English Spanish German Done French Display Language Configuration...

Page 13: ...gled through Speed RPM and your selected Display Rate by pressing the right arrow button Press MENU button to enter the menu structure Select Configuration and Press ENTER button Select Display Rate a...

Page 14: ...wrate Flowrate ML min Press ENTER to set 0000 0 1 Contact Input Close Stop Pump Open Stop Pump Input Time Delay OFF 000 Range 1 255 sec Disable 00 0 Input Setup 4 20 mA Input Frequency Input Pulse Inp...

Page 15: ...rate Input Modes Contact Input Set FVS Esc Hidden Remote Local Set DFD Set Rev Alarm Max Flowrate Input Max Flowrate Flowrate ML min Press ENTER to set 0000 0 1 To calculate the Max Flowrate To determ...

Page 16: ...ack out of the menu structure To do this you must select Esc at the bottom of every screen menu until you see the Run Mode screen displayed Tip The Manual Speed Adjust mode can be combined with Contac...

Page 17: ...process until all four screens have been configured If you used short cut to enter 4 20 mA input setup press and hold the Mode button until the Run Mode screen is displayed If you used Menu button to...

Page 18: ...top line of the display To configure the pump navigate to 0 10 VDC Input menu by using the short cut method described at the beginning of the section or by pressing MENU button then selecting Input Se...

Page 19: ...select the digit to change press UP or DOWN arrow to scroll through 0 9 on selected digit Press enter to save changes and move to the next input screen To input flow rate values press the RIGHT ARROW...

Page 20: ...k by continuously pressing the RIGHT button Press ENTER to save the changes Continue this process until all three screens have been configured If you used the short cut to enter Pulse Batch setup then...

Page 21: ...onfigured If you used the short cut to enter Manual Cycle Adjustment setup press and hold Mode button until Run Mode screen is displayed If you used the Menu button to navigate to Cycle Adjustment set...

Page 22: ...xt digit to the right If you pass your desired digit you can easily scroll back by continuously pressing RIGHT button Press ENTER to save the changes Continue this process until two screens have been...

Page 23: ...arrow to scroll over to next digit to the right If you pass your desired digit you can easily scroll back by continuously pressing RIGHT button Press ENTER to save the changes Continue this process un...

Page 24: ...esired digit you can easily scroll back by continuously pressing RIGHT button Press ENTER to save the changes Continue this process until all four screens have been configured If you used the short cu...

Page 25: ...gering due to flickering high speed electrical switches a trigger delay time can be configured to delay the pump command The delay time unit of measure is seconds A two second delay time is recommende...

Page 26: ...n discharge side of MD3 pump Wiring for sensor can be connected directly to a MD3 pump Pump will stop pumping if sensor detects no flow A relay will then close allowing for remote alarm indication or...

Page 27: ...an 430 microsiemens will not be detected This system is capable of detecting presence of a large number of chemicals including Sodium Hypochlorite Chlorine Hydrochloric muriatic Acid Sodium Hydroxide...

Page 28: ...etting section 4 4 is switched to disabled while LOCAL ONLY is selected This menu setting will return to the previous setting when REMOTE ONLY or DISABLED is selected Input Setup Input Modes Contact I...

Page 29: ...Stop Frequency Mode Cycle Timer Mode Dispensing Mode Manual Dosing Prop Dosing 0 10 VDC Mode Pulse Mode Disable FVS DFD Pump Run Stop 4 20mA Mode Manual Mode Frequency Mode Cycle Timer Mode Dispensing...

Page 30: ...0 Pump Output 4 mA 100 Pump Output 20 mA Signal Output Frequency Output Disable Done 4 20 mA Output Default 4 20 mA output settings shown Signal Output Disable Done 4 20 mA Output Default Frequency H...

Page 31: ...r does not assume responsibility for damage to pump that has been caused by chemical attack 6 2 Cleaning Pump Pump will require occasional cleaning especially Injection fitting Footvalve Strainer and...

Page 32: ...7 0 Exploded view and parts list 1 2 4 6 8 7 10 22 9 15 14 3 13 11 3 12 Page 32 CHEM FEED MD3...

Page 33: ...001 505 MANIFOLD WITH FLANGE AND UNION NUT PLUG WITH O RING EP 6 90002 350 DRIVE HEAD INSERT 2 7 72000 583 KIT DIAPHRAGM PVDF MD3 2 8 70001 345 CARTRIDGE VALVE TFE P 8 70001 346 CARTRIDGE VALVE EP 9 9...

Page 34: ...32 151 303 751 1508 2252 3041 RPM 1 3 10 19 48 95 142 190 GPH 0 5 2 4 4 8 11 9 23 9 35 7 48 2 Feed Rate at 90 PSIg ML MIN 25 145 278 694 1388 2107 2391 RPM 1 3 10 19 48 95 142 190 GPH 0 4 2 3 4 4 11 0...

Page 35: ...Page intentionally left blank Page 35 CHEM FEED MD3...

Page 36: ...Page intentionally left blank Page 36 CHEM FEED MD3...

Page 37: ...Page intentionally left blank Page 37 CHEM FEED MD3...

Page 38: ...iption of the problem and proof of purchase Prepay all shipping and insurance cost COD shipments will not be accepted Damage caused by improper packaging is the responsibility of the sender When In Wa...

Page 39: ...ia New Zealand 9 230V 50HZ power cord BS 1363 A plug United Kingdom X No Power Cord Elastomer Material O Rings V TFE P E EP Miscellaneous Options leave blank for standard model A Hastelloy C check val...

Page 40: ...ramework available to them for the return recycle recovery of WEEE and minimize any potential effects of EEE on the environment and human health due to the presence of hazardous substances The WEEE ma...

Reviews: