background image

TABLE OF CONTENTS

1

.....Introduction .....................................................................................

3

2

.....Specifications............. .............. .............. .............. .............. ..............

3

3

.....Features........ .............. .............. .............. .............. .............. ..............

3

4

.....Unpacking.... .............. .............. .............. .............. .............. ..............

3

5

.....Installation ... .............. .............. .............. .............. .............. ..............

4

 

5.1

..Mounting location ............. .............. .............. .............. ..............

4

 

5.2

..Input power connections ... .............. .............. .............. ..............

5

 

5.3

..External input signal connections.... .............. .............. ..............

6

 

5.4

..How to install the tubing and fittings............. .............. ..............

8

6

.....How to operate the Pump ......... .............. .............. .............. ..............

9

 

6.1

..How to adjust the output - manual stroke adjustment ................

9

 

6.2

..Electronic pump output controls ..... .............. .............. ..............

10

 

6.3

..Mode 0 - FVS System set-up........... .............. .............. ..............

10

 

6.4

..Mode 1 - Manually Adjusting the output....... .............. ..............

13

 

6.5

..Mode 2 - 4-20 mA input.... .............. .............. .............. ..............

14

 

6.6

..Mode 3 - 0-10 VDC input . .............. .............. .............. ..............

16

 

6.7

..Mode 4 - Frequency (Hz) input ....... .............. .............. ..............

19

 

6.8

..Mode 5 - Pulse input (Batch)........... .............. .............. ..............

20

 

6.9

..Measuring the pump output - Volumetric test .............. ..............

21

7

.....How to maintain the Pump....... .............. .............. .............. ..............

22

 

7.1

..Routine inspection and cleaning...... .............. .............. ..............

22

 

7.2

..How to clean the pump ..... .............. .............. .............. ..............

22

 

7.3

..500 hour service warning timer ....... .............. .............. ..............

22

 

Pump head and Valve exploded view drawing ..... .............. ..............

23

 

Replacement parts drawing ...... .............. .............. .............. ..............

24

 

Replacement parts list .............. .............. .............. .............. ..............

25

 

Warranty information. .............. .............. .............. .............. ..............

26

 

Authorized service centers ....... .............. .............. .............. ..............

27

Page 2

2.0 

Specifications

Maximum Working Pressure   

150 psig / 10.4 bar (most models)

Maximum Fluid Temperature 

                     130  F / 54 C

o

Ambient Temperature Range

   

14 to 110 F / -10 to 43 C

Duty Cycle

 

 

 

Continuous

Maximum Viscosity

 

 

1,000 Centipoise

Maximum Suction Lift

 

 

up to 20 ft. water

Power Requirements

 

 

115V/60Hz 14 & 30 RPM (1.37A max.)

 

 

 

 

115V/60Hz 45, 60, 125, 250 RPM (1.87A   max.)

 

 

 

 

230V/60Hz 14 & 30 RPM (0.64A max.)

 

 

 

 

230V/60Hz 45, 60, 125, 250 RPM (0.74A max.)

 

 

 

 

220V/50Hz 14 & 30 RPM (0.68A max.)

 

 

 

 

220V/50Hz 45, 60, 125, 250 RPM (1.14A max.)

 

 

 

 

240V/50Hz 14 & 30 RPM (0.66A max.)

 

 

 

 

240V/50Hz 45, 60, 125, 250 RPM (1.04A max.)

Dimensions

 

 

 

6-1/4” H x 10-1/8” W x 9” D

Weight

 

 

 

8 lb. / 3.6 Kg

Page 3

1.0 Introduction

Congratulations on purchasing the C-1100 Model-E positive displacement 
metering pump.  The C-1100 is designed to inject chemicals into piping 
systems and is capable of injecting against a high system pressure up to 150 
PSI (10.4 bar).  In addition to the front mounted mechanical flow rate 
adjustment, the C-1100 Model-E unit is equipped with an external input 
control circuitry which allows the pumps output to be externally controlled 
by either a 4-20mA input signal, a 0-10V DC input signal or a pulsed input 
signal.

C-1100E

C-1100E

4.0 Unpacking

Your pump package should contain the following:
1 - Injector pump
1 - suction tube footvalve & strainer assembly
1 - ceramic tubing weight
1 - 5’ Length of clear PVC suction tubing
1 - 5’ Length of opaque LLDPE discharge tubing
1 - Injection fitting with internal back-flow check valve
1 - Mounting hardware kit

3.0 Features

!

Double-ball, springless ceramic check valves with PVDF (Kynar) body,
TFE/P (Aflas) and Viton o-ring seals.

!

Easy access, front mounted mechanical feed rate adjustment.

!

High outlet pressure capability of 150 psig (most models).

!

4000:1 adjustment turn down ratio.

!

Digital electronic feed rate control.

!

Corrosion proof Valox housing.

!

Tamper resistant electronic control panel cover.

Summary of Contents for CHEM-FEED C-1100E

Page 1: ...2649 USA Phone 714 893 8529 FAX 714 894 9492 E mail sales blue white com or techsupport blue white com Website www blue white com Blue White Industries Ltd R INJECTOR MODEL C 1100 MODEL E POSITIVE DIS...

Page 2: ...10 6 3 Mode 0 FVS System set up 10 6 4 Mode 1 Manually Adjusting the output 13 6 5 Mode 2 4 20 mA input 14 6 6 Mode 3 0 10 VDC input 16 6 7 Mode 4 Frequency Hz input 19 6 8 Mode 5 Pulse input Batch 2...

Page 3: ...a high system pressure up to 150 PSI 10 4 bar In addition to the front mounted mechanical flow rate adjustment the C 1100 Model E unit is equipped with an external input control circuitry which allows...

Page 4: ...should be sturdy Keep the tank covered to reduce fumes Do not mount the pump directly over your tank Chemical fumes may damage the unit Mount the pump off to the side or at a lower level than the chem...

Page 5: ...7 Circuit Board Connections diagram for details The pump is supplied with a ground wire conductor and a grounding type attachment plug power cord To reduce the risk of electric shock be certain that t...

Page 6: ...50Hz HOT LEADWIRE NEUTRAL LEADWIRE GROUND LEADWIRE 230V 60Hz YELLOW YELLOW YELLOW BLUE BROWN RED GREEN GREEN GREEN MOTOR LEADWIRES SIGNAL INPUT WIRE COLOR CODES WIRE COLOR CODE INPUT TYPE MOTOR ON SIG...

Page 7: ...GND BLACK RELAY PURPLE 2 VDC ORANGE VS RED 17V DC PLS WHITE JUNCTION BOX LIQUID TIGHT CONNECTOR MTR BROWN Alarm Relay 3A 125VAC N C COM N O Purple connection wires Default is N O VS VDC MA MTR GND PL...

Page 8: ...ing is designed to install directly into either 1 4 or 1 2 female pipe threads This fitting will require periodic cleaning especially when injecting fluids that calcify such as sodium hypochlorite See...

Page 9: ...How To Operate The Pump 6 1 How to adjust the output manual stroke adjustment The Pump flow rate can be adjusted within a range of 5 100 of maximum output 20 1 turndown ration by means of a mechanica...

Page 10: ...ton initiates the programming mode The ARROW next to the word PROGRAM will blink FIELD Button In the programming mode selects the digit to be changed DIGIT Button In the programming mode increases the...

Page 11: ...lue of 000 seconds disables the FVS system The pump will stop and the alarm mode activated if no pulses are received by the pump and the alarm delay time period has ended Press the STAND BY button twi...

Page 12: ...cuitry will automatically return to the run mode The TFD system The TFD icon will blink The TFD system is only used on A 100N series peristaltic pumps The word ON will display indicating the TFD syste...

Page 13: ...tly RUN PROGRAM STAND BY PRIME MINIMUM MAXIMUM 1 199 9 MODE TOT T SEC RUN PROGRAM STAND BY PRIME MINIMUM MAXIMUM 1 42 5 MODE ON T SEC selected time unit icon will be displayed The current total time s...

Page 14: ...14 16 18 20 0 2 4 6 8 Pump Run Time Sec Milliamp input mA Page 14 Set the pump for mode 2 Press the MODE button until MODE 2 is shown on the LCD display Enter the programming mode At the same time pre...

Page 15: ...ogramming screen and enter the total time programming screen The total time TOT T icon will blink The currently selected time unit icon will be displayed The current total time setting will be display...

Page 16: ...OGRAM STAND BY PRIME MINIMUM MAXIMUM 3 00 0 MODE ON T SEC Set the pump for mode 3 Press the MODE button until MODE 3 is shown on the LCD display Enter the programming mode At the same time press the R...

Page 17: ...nimum programming screen and enter the total time programming screen The total time TOT T icon will blink The currently selected time unit icon will be displayed The current total time setting will be...

Page 18: ...MODE 4 is shown on the LCD display Enter the programming mode At the same time press the RUN STANDBY button and the MODE button A blinking ARROW will point to the word PROGRAM indicating the program...

Page 19: ...nimum programming screen and enter the total time programming screen The total time TOT T icon will blink The currently selected time unit icon will be displayed The current total time setting will be...

Page 20: ...ng screen The HZ icon will blink A blinking ARROW will appear next to the word MAXIMUM The current Hz setting will be displayed and the left most selected digit will blink icon will be displayed The c...

Page 21: ...stalled in the graduated cylinder 4 Run the pump until all air is removed from the suction line and the solution enters the discharge tubing If the pump does not easily prime remove the discharge tubi...

Page 22: ...itting the Footvalve Strainer and the pump head valves The frequency will depend on the type and severity of service Inspect and replace the pumphead valves as required When changing the diaphragm the...

Page 23: ...Page 23 C 1100E PUMP HEAD AND VALVE EXPLODED VIEW...

Page 24: ...T OFF P2 4 20 mA NOR MAL P3 20 4 mA INVE RTE D P4 0 10 VDC NOR MAL P5 10 0 VDC INVE RTE D P6 SLO W PUL SE X 1 P7 FAS T PUL SE X 100 99 SEC CYC LE ADJ UST CYC LE WHE N LIT ADJ UST CYC LE WHE N LIT 500...

Page 25: ...de Bearing 2 21 76000 172 Stirr up 1 22 90002 017 Dial Knob 1 23 90011 168 Screw 6 x 62 PH oval A 4 24 90011 121 Thumb Screw 6 32 x 1 125 1 25 71000 363 Cover Cam S A C 1100 1 26 90006 597 Gasket Top...

Page 26: ...al label and the sales invoice or receipt The serial label must be on the pump and the pump must be accompanied by the sales invoice or receipt to obtain warranty coverage The warranty status of the p...

Page 27: ...ahassee FL 32304 850 575 9618 Jerry Lee Chemical Co 3407 W Old Fairfield Drive Pensacola FL 32505 904 432 9929 Picard Chemical 1670 S Congress Avenue W Palm Beach FL 33406 561 965 3434 ILLINOIS Mullar...

Page 28: ...v 3 03 17 2020 5300 Business Drive Huntington Beach CA 92649 USA Phone 714 893 8529 FAX 714 894 9492 E mail sales blue white com or techsupport blue white com Website www blue white com Blue White Ind...

Reviews: