6.7 Mode 4 - Frequency (Hz) input - 

In this mode, the on-time of the 

cycle will automatically adjust to match the received Hz input value. When 
the Hz value is equal the programmed maximum, the pump will run 
continuously. 
Four values must be programmed:
1) 

ON-T

 = The amount of time the pump will run, per cycle, when the 

minimum hZ value is received. (Typically programmed to zero)

2) 

Hz minimum

 = The Hz input value that will result in the on time (

ON-

T

). (Typically programmed to 0 Hz)

3) 

TOT-T

 = The total cycle time.

4) 

Hz maximum

 = The Hz input value that will result in the pump running 

continuously. 

Page 18

Page 19

RUN

PROGRAM

STAND-BY

PRIME

MINIMUM

MAXIMUM

4

00.0

MODE

ON-T

SEC

RUN

PROGRAM

STAND-BY

PRIME

MINIMUM

MAXIMUM

4

08.0

MODE

SEC

TOT-T

+

Set the pump for mode 4

. Press the 

MODE button until 

MODE 4

 is shown on 

the LCD display.

+

Enter the programming mode.

 At the 

same time, press the RUN/STANDBY 
button and the MODE button. A blinking 

ARROW

 

will point to the word 

PROGRAM 

indicating the program mode has been 
activated. The on time 

ON-T

 icon will 

blink. The currently selected time unit 

+

Press the MODE button to exit the on time 
programming screen and enter the Hz 
minimum programming screen. The 

HZ

 

icon will blink. A blinking 

ARROW

 will 

appear next to the word 

MINIMUM

. The 

current minimum Hz setting will be 
displayed and the left most (selected) digit 
will blink. 

icon will be displayed. The current on time setting will be displayed and 
the left most (selected) digit will blink.  Note: The left most digits can be 
programmed from 0 - 19. The decimal is fixed and cannot be moved.

+

Pressing the DIGIT button will increase the selected digit.

+

Pressing the FIELD button will select a new digit to the right or the time 
unit.

+

Press the DIGIT button to increase the selected digit or time unit.

+

Pressing the DIGIT button will increase the selected digit.

+

Pressing the FIELD button will select a new digit to the right.

+

Press the DIGIT button to increase the selected digit.

(selected) digit will blink.  Note: The left most digit can be programmed 
from 0 - 19. The decimal is fixed and cannot be moved.

+

Pressing the DIGIT button will increase the selected digit.

+

Pressing the FIELD button will select a new digit to the right or the time 
unit.

+

Press the DIGIT button to increase the selected digit or time unit.

+

Press the MODE button to exit the Hz 
minimum programming screen and enter 
the total time programming screen. The 
total time 

TOT-T

 icon will blink. The 

currently selected time unit icon will be 
displayed. The current total time setting 
will be displayed and the left most 

+

Press the MODE button to exit the total 
time programming screen and enter the Hz 
maximum programming screen. The 

HZ

 

icon will blink. A blinking 

ARROW

 will 

appear next to the word 

MAXIMUM

. The 

current maximum Hz setting will be 
displayed and the left most (selected) digit 
will blink.

+

Pressing the DIGIT button will increase the selected digit.

+

Pressing the FIELD button will select a new digit to the right.

+

Press the DIGIT button to increase the selected digit.

+

At the same time, press the RUN/STANDBY button and the MODE 
button. A blinking 

ARROW

 

will point to the word 

RUN 

indicating the run 

mode has been activated.

ø

NOTE: 

If while in the program mode no buttons are pressed within 60 

seconds, the circuitry will automatically return to the run mode.

Example: 
ON-T setting = 0 seconds
Hz minimum setting = 0 Hz
TOT-T setting = 8 seconds
Hz

 

maximum setting = 425 Hz

1

0

2 3

5 6 7 8

10

0

2

4

6

8

Pump Run-T

ime (Sec.)

Frequency input (x100)

4

9

1

3

5

7

RUN

PROGRAM

STAND-BY

PRIME

MINIMUM

MAXIMUM

4

425

MODE

Hz

RUN

PROGRAM

STAND-BY

PRIME

MINIMUM

MAXIMUM

4

000

MODE

Hz

C-1100E

C-1100E

Summary of Contents for CHEM-FEED C-1100E

Page 1: ...2649 USA Phone 714 893 8529 FAX 714 894 9492 E mail sales blue white com or techsupport blue white com Website www blue white com Blue White Industries Ltd R INJECTOR MODEL C 1100 MODEL E POSITIVE DIS...

Page 2: ...10 6 3 Mode 0 FVS System set up 10 6 4 Mode 1 Manually Adjusting the output 13 6 5 Mode 2 4 20 mA input 14 6 6 Mode 3 0 10 VDC input 16 6 7 Mode 4 Frequency Hz input 19 6 8 Mode 5 Pulse input Batch 2...

Page 3: ...a high system pressure up to 150 PSI 10 4 bar In addition to the front mounted mechanical flow rate adjustment the C 1100 Model E unit is equipped with an external input control circuitry which allows...

Page 4: ...should be sturdy Keep the tank covered to reduce fumes Do not mount the pump directly over your tank Chemical fumes may damage the unit Mount the pump off to the side or at a lower level than the chem...

Page 5: ...7 Circuit Board Connections diagram for details The pump is supplied with a ground wire conductor and a grounding type attachment plug power cord To reduce the risk of electric shock be certain that t...

Page 6: ...50Hz HOT LEADWIRE NEUTRAL LEADWIRE GROUND LEADWIRE 230V 60Hz YELLOW YELLOW YELLOW BLUE BROWN RED GREEN GREEN GREEN MOTOR LEADWIRES SIGNAL INPUT WIRE COLOR CODES WIRE COLOR CODE INPUT TYPE MOTOR ON SIG...

Page 7: ...GND BLACK RELAY PURPLE 2 VDC ORANGE VS RED 17V DC PLS WHITE JUNCTION BOX LIQUID TIGHT CONNECTOR MTR BROWN Alarm Relay 3A 125VAC N C COM N O Purple connection wires Default is N O VS VDC MA MTR GND PL...

Page 8: ...ing is designed to install directly into either 1 4 or 1 2 female pipe threads This fitting will require periodic cleaning especially when injecting fluids that calcify such as sodium hypochlorite See...

Page 9: ...How To Operate The Pump 6 1 How to adjust the output manual stroke adjustment The Pump flow rate can be adjusted within a range of 5 100 of maximum output 20 1 turndown ration by means of a mechanica...

Page 10: ...ton initiates the programming mode The ARROW next to the word PROGRAM will blink FIELD Button In the programming mode selects the digit to be changed DIGIT Button In the programming mode increases the...

Page 11: ...lue of 000 seconds disables the FVS system The pump will stop and the alarm mode activated if no pulses are received by the pump and the alarm delay time period has ended Press the STAND BY button twi...

Page 12: ...cuitry will automatically return to the run mode The TFD system The TFD icon will blink The TFD system is only used on A 100N series peristaltic pumps The word ON will display indicating the TFD syste...

Page 13: ...tly RUN PROGRAM STAND BY PRIME MINIMUM MAXIMUM 1 199 9 MODE TOT T SEC RUN PROGRAM STAND BY PRIME MINIMUM MAXIMUM 1 42 5 MODE ON T SEC selected time unit icon will be displayed The current total time s...

Page 14: ...14 16 18 20 0 2 4 6 8 Pump Run Time Sec Milliamp input mA Page 14 Set the pump for mode 2 Press the MODE button until MODE 2 is shown on the LCD display Enter the programming mode At the same time pre...

Page 15: ...ogramming screen and enter the total time programming screen The total time TOT T icon will blink The currently selected time unit icon will be displayed The current total time setting will be display...

Page 16: ...OGRAM STAND BY PRIME MINIMUM MAXIMUM 3 00 0 MODE ON T SEC Set the pump for mode 3 Press the MODE button until MODE 3 is shown on the LCD display Enter the programming mode At the same time press the R...

Page 17: ...nimum programming screen and enter the total time programming screen The total time TOT T icon will blink The currently selected time unit icon will be displayed The current total time setting will be...

Page 18: ...MODE 4 is shown on the LCD display Enter the programming mode At the same time press the RUN STANDBY button and the MODE button A blinking ARROW will point to the word PROGRAM indicating the program...

Page 19: ...nimum programming screen and enter the total time programming screen The total time TOT T icon will blink The currently selected time unit icon will be displayed The current total time setting will be...

Page 20: ...ng screen The HZ icon will blink A blinking ARROW will appear next to the word MAXIMUM The current Hz setting will be displayed and the left most selected digit will blink icon will be displayed The c...

Page 21: ...stalled in the graduated cylinder 4 Run the pump until all air is removed from the suction line and the solution enters the discharge tubing If the pump does not easily prime remove the discharge tubi...

Page 22: ...itting the Footvalve Strainer and the pump head valves The frequency will depend on the type and severity of service Inspect and replace the pumphead valves as required When changing the diaphragm the...

Page 23: ...Page 23 C 1100E PUMP HEAD AND VALVE EXPLODED VIEW...

Page 24: ...T OFF P2 4 20 mA NOR MAL P3 20 4 mA INVE RTE D P4 0 10 VDC NOR MAL P5 10 0 VDC INVE RTE D P6 SLO W PUL SE X 1 P7 FAS T PUL SE X 100 99 SEC CYC LE ADJ UST CYC LE WHE N LIT ADJ UST CYC LE WHE N LIT 500...

Page 25: ...de Bearing 2 21 76000 172 Stirr up 1 22 90002 017 Dial Knob 1 23 90011 168 Screw 6 x 62 PH oval A 4 24 90011 121 Thumb Screw 6 32 x 1 125 1 25 71000 363 Cover Cam S A C 1100 1 26 90006 597 Gasket Top...

Page 26: ...al label and the sales invoice or receipt The serial label must be on the pump and the pump must be accompanied by the sales invoice or receipt to obtain warranty coverage The warranty status of the p...

Page 27: ...ahassee FL 32304 850 575 9618 Jerry Lee Chemical Co 3407 W Old Fairfield Drive Pensacola FL 32505 904 432 9929 Picard Chemical 1670 S Congress Avenue W Palm Beach FL 33406 561 965 3434 ILLINOIS Mullar...

Page 28: ...v 3 03 17 2020 5300 Business Drive Huntington Beach CA 92649 USA Phone 714 893 8529 FAX 714 894 9492 E mail sales blue white com or techsupport blue white com Website www blue white com Blue White Ind...

Reviews: