6.8 Mode 5 - Pulse input (Batch) -
In this mode, when the total number
of accumulated pulses is equal to the programmed pulse input value (Hz) ,
the pump will run for the programmed on time.
Two values must be programmed:
1)
ON-T
= The amount of time the pump will run when accumulated pulses
is equal to the programmed pulse input value (Hz).
2)
Hz maximum
= The number of input pulses that will trigger the batch.
+
Set the pump for mode 5
. Press the MODE button until
MODE 5
is
shown on the LCD display.
Page 20
Page 21
RUN
PROGRAM
STAND-BY
PRIME
MINIMUM
MAXIMUM
5
00.0
MODE
ON-T
SEC
+
Enter the programming mode.
At the
same time, press the RUN/STANDBY
button and the MODE button. A blinking
ARROW
will point to the word
PROGRAM
indicating the program mode has been
activated. The on time
ON-T
icon will
blink. The currently selected time unit
+
Press the MODE button to exit the on time
programming screen and enter the Hz
(pulses per batch) programming screen.
The
HZ
icon will blink. A blinking
ARROW
will appear next to the word
MAXIMUM
.
The current Hz setting will be displayed
and the left most (selected) digit will
blink.
icon will be displayed. The current on time setting will be displayed and
the left most (selected) digit will blink. Note: The left most digits can be
programmed from 0 - 19. The decimal is fixed and cannot be moved.
+
Pressing the DIGIT button will increase the selected digit.
+
Pressing the FIELD button will select a new digit to the right or the time
unit.
+
Press the DIGIT button to increase the selected digit or time unit.
+
Pressing the DIGIT button will increase the selected digit.
+
Pressing the FIELD button will select a new digit to the right.
+
Press the DIGIT button to increase the selected digit.
+
At the same time, press the RUN/STANDBY button and the MODE
button. A blinking
ARROW
will point to the word
RUN
indicating the run
mode has been activated.
ø
NOTE:
If while in the program mode no buttons are pressed within 60
seconds, the circuitry will automatically return to the run mode.
RUN
PROGRAM
STAND-BY
PRIME
MINIMUM
MAXIMUM
5
000
MODE
Hz
C-1100E
C-1100E
6.9 Measuring the Pump’s Output - Volumetric Test.
This volumetric test will take into account individual installation factors
such as line pressure, fluid viscosity, suction lift, etc. This test is the most
accurate for measuring the injector’s output in an individual installation.
1. Be sure the Injection Fitting and Footvalve/Strainer is clean and working
properly.
2. Fill a large graduated cylinder with the solution to be injected.
3. With the pump installed under normal operating conditions, place the
suction tubing with the Footvalve/Strainer installed in the graduated
cylinder.
4. Run the pump until all air is removed from the suction line and the solution
enters the discharge tubing. If the pump does not easily prime, remove the
discharge tubing from injection fitting until the pump primes. Re-connect
the discharge tubing to the injection fitting.
5. Remove the suction tubing from the graduated cylinder and refill the
graduated cylinder if necessary. Note the amount of solution in the gradu-
ated cylinder.
6. Place suction tubing with the Footvalve/Strainer installed back into the
graduated cylinder.
7. Run the injector for a measured amount of time. A longer testing time will
produce more accurate results.
8. Remove the suction tubing from the graduated cylinder. Measure the
amount of chemical injected.