Possible Reasons
No.
Problem
Cause
Rectification
4
Water tank is filling
very fast. High water
flow
1. Water flow circuit is not properly
connected.
2.R.O. Membrane is not in housing.
3. Defective FRT.Rejection Rate is very
low.
4. Pipe connection of filtered water &
reject water is interchanged.
1.Connect the water flow circuit as per
manual.
2.Put the R.O. Membrane in the housing.
3.Change the FRT with standard rating.
4.Correct the water flow conncetion.
5
Purification indicator
is ON when there is
no source water.
1.Faulty electrical wire connection
2. LPS is defective.
1. Correct the electrical wiring
connections.
2. Change the LPS.
6
Alert sound is
coming from the
device.
1.Filter Change alert.
2.Electrical connection is Loose or
disconnected from UV lamp.
3.UV fail alert.
4.Defective Filter Change indicator
giving false alert.
5.Check electrical wiring connection.
1.Check the Filter Change Indicator if the
indicator reading is close to Zero it is filter
change alert.
2.Connect electrical connection to UV
properly.
3.Check if UV is working or not by light
reflecting from ends of the UV chamber.
If UV is not working then change UV
Chamber.
4.Change Filter change Indicator.
5.Make the proper electrical wiring
connection as shown on the device.