Troubleshooting
1. Water leakage
•
In case of a water leak inside the purifier, turn off the water supply and unscrew the side panel cover of
the purifier.
•
Remove the side panel cover for a deeper analysis of the root cause of the leak.
Possible Reasons
Defect
Cause
Rectification
WATER
LEAKAGE
INSIDE THE
PURIFIER
1. Certain tubings inside are loosely connected.
Identify the loose tubing and tighten the connection. If
the problem still persists replace the tubing.
2. Certain connectors or tubings inside the
purifier are damaged/defective.
Identify the defective connector and replace it with a
new one.
3. The input/output connectors of the Filters/
RO Membrane housing/UV lamp/Booster Pump
housing are damaged/defective.
Identify which component has the defective connector
and replace it with a new one.
4. The Solenoid valve manifold is
damaged/defective.
Replace the entire solenoid valve.
5. The Water level sensor doesn't work (TANK
OVERFLOW ISSUE) because of faulty electrical
wiring connection or Defective float sensor.
1. Check the electrical connections and connect it
properly.
2.Check the Electrical float sensor if found defective
replace it.