PRO LINE DUCT INFORMATION
MODEL
BLOWER (cfm)
DUCT SIZE
TRANSITION
BS-PL30240
BS-PLIB600
6”
BS-PL30240
BS-PLIB1200
10”
BS-PL36240
BS-PLIB600
6”
BS-PL36240
BS-PLIB1200
10”
TR6X15/10
BS-PL42240
BS-PLIB600
6”
BS-PL42240
BS-PLIB1200
10”
TR6X15/10
BS-PL48240
BS-PLIB1200
10”
TR6X15/10
BS-PL54240
BS-PLIB1200
10”
TR6X15/10
BS-PL60240
BS-PLIB1200
10”
TR6X15/10
BS-PL66240
BS-PLIB1200
10”
TR6X15/10
BS-PLIB600 IS SIZED FOR A 6” DUCT. TRC8/6 TRANSITION IS AVAILABLE TO INCREASE THE DUCT
SIZE TO 8” FOR OPTIMAL PERFORMANCE
IMPORTANT PLANNING INFORMATION!
PROPER INSTALLATION OF DUCTING IS EXTREMELY INPORTANT FOR OPTIMAL PERFORMANCE OF
YOUR BLUESTAR VENTILLATION SYSTEM.
ALL CFM’S ARE BASED ON TESTS AT 0.1 STATIC PRESSURE; WITHOUT STATIC PRESSURE, ALL
CFM’S WOULD BE OVERSTATED.
STRAIGHT RUNS OR GRADUAL TURNS ARE BEST
NEVER USE FLEXIBLE DUCT WORK
PROPER PERFORMANCE IS DEPENDENT ON PROPER DUCT INSTALLATION, USE A QUALIFIED
AND TRAINED INSTALLER
CONSULT WITH LOCAL CODES FOR MAKE UP AIR REQUIREMENTS
L-BRACKETS FOR THE INTERNAL BLOWER PACKAGES CAN BE MOUNTED FOR EITHER TOP OR
REAR DISHARGE
BS-PLIB1200 BLOWERS REQUIRE AN ADDITIONAL PURCHASE OF A 10” TRANSITION