-7-
Revision 6/F3503
©
Moffat Ltd, April 2005
E26 Convection Oven
RATING PLATE LOCATION
The rating plate for the E26 convection oven
is located at the bottom left corner of the RH
side panel.
It is most important that the oven is installed
correctly and that the operation is correct
before use. Installation shall comply with local
electrical, health and safety requirements.
BEFORE CONNECTION TO POWER
SUPPLY
Unpack and check unit for damage and report
any damage to the carrier and dealer. Report
any deficiencies to your dealer. Check that
the available power supply is correct to that
shown on the rating plate located on the right-
hand side panel.
E26
220Vac, 50/60Hz, 11A, 2.4kW @ 220V
230-240Vac, 50Hz, 10A, 2.4kW @ 240V
LOCATION
To ensure correct ventilation for the motor,
and controls the following minimum
installation clearances are to be adhered to:
Top
200mm / 8”
Rear
25mm / 1”
Left-hand side
25mm / 1”
Right-hand side
25mm / 1”
2. INSTALLATION
WARNING: THIS APPLIANCE MUST BE GROUNDED.
ELECTRICAL CONNECTION
E26 convection ovens are supplied with
pre-fitted cords. Ensure unit is fitted with the
correct cord and plug for the installation.
Refer specifications section.
Should changing of the cord be necessary,
gain access to the electrical connection
terminal block, grounding lug, and strain relief
by removing the back panel (four screws).
Figure 2.1
WARNING: ALL INSTALLATION AND SERVICE REPAIR WORK MUST BE CARRIED
OUT BY QUALIFIED PERSONS ONLY.
Position the oven in its allocated working
position. Use a spirit level to ensure the oven
is level from side to side and front to back. (If
this is not carried out, uneven cooking could
occur). The feet used with bench
mounting are adjustable and will require
adjusting in levelling the unit. It should be
positioned so the operating panel and oven
shelves are easily reachable for loading and
unloading.
BEFORE USE
Operate the oven for about 1 hour at 200°C
(400°F) to remove any fumes or odours which
may be present.
IMPORTANT:
THE OVEN VENT
LOCATED ON THE CABINET TOP
MUST NEVER BE OBSTRUCTED.
Rating Plate
Figure 2.2
L1
L2
Ground
Phase
Neutral
RED
BROWN
BLACK
GREEN/YELLOW
GREEN
WARNING:
THIS APPLIANCE MUST
BE GROUNDED / EARTHED
BLACK
BLUE
WHITE