Appendix A: Gas Type Conversion
38
© Moffat Ltd, January 2007
Revision 1/
Blue Seal Evolution Series Gas Griddles
Commissioning
Before leaving the converted installation;
1.
Check all gas connections for leakages using soapy water or other gas detecting equipment.
2.
Check the following functions in accordance with the operating instructions specified in the
“Operation” section of the User manual.
•
Light the Pilot Burner.
•
Light the Main Burner.
•
Check the ‘Low Fire’ burner operation.
•
Check the ‘High Fire’ Burner operation.
•
Ensure that all the controls operate correctly.
•
Ensure that the operating pressure remains correct.
3.
Ensure any adjustments done to components that have the adjustments/settings sealed (e.g. paint
sealed) are re-sealed.
NOTE: If for some reason it is not possible to get the appliance to operate correctly, shut off the
gas supply and contact the supplier of this appliance.
Gas Specifications
- Non-UK Only
Natural Gas
LP Gas (Propane)
GP514
GP516
GP518
GP514
GP516
GP518
3.60
3.00
2.85
2.10
1.80
1.70
Pilot Burner Injector
0.41
0.25
Low Fire Adjustment
1 Full Turn Counter Clockwise from the 'Fully In' Position
High Fire Adjustment
Maximum Flow Screw. Fully In c.w. (Note 1)
Operating Pressure
0.85 kPa
(Note 2)
2.5 kPa
(Note 2)
2.6 kPa
(Note 2)
Gas Regulator Cap
Screw
0.90 kPa
(Note 2)
Main Burner Injector
Supply Pressure
1.13 - 3.40 kPa
(4.5” - 13.5” w.c.)
2.75 - 3.40 kPa
(11” - 13.5” w.c.)
WARNING:
D
O
NOT
USE
A
NAKED
FLAME
TO
CHECK
FOR
GAS
LEAKAGES
.