2
Installation
9
© Moffat Ltd, January 2007
Revision 1/
Blue Seal Evolution Series Gas Griddles
The regulator connections are
3
/
4
" BSP female.
The connection to the appliance is
3
/
4
" BSP male.
(Refer to the “Specifications” section for the gas supply location dimensions).
NOTE: A Manual Isolation Valve must be fitted to the individual appliance supply line.
4.
Correctly locate the appliance into its final operating position and using a spirit level, adjust the legs
so that the unit is level and at the correct height.
5.
Connect the gas supply to the appliance. A suitable jointing compound which resists the
breakdown action of LPG must be used on every gas line connection, unless compression fittings are
used.
6.
Check all gas connections for leakages using soapy water or other gas detecting equipment.
7.
Check that the gas operating pressure is as shown in the “Specifications” section.
NOTE:
The operating pressure is to be
measured at the burner operating
pressure test point outlet and with one
griddle burner operating at the “High
Flame” setting.
8.
Turn off the mains gas supply and bleed the
gas out of the appliance gas lines.
9.
Turn on the gas supply and the appliance.
10. Verify the operating pressure remains
correct.
Commissioning
Before leaving the new installation;
Check the following functions in accordance with the operating instructions specified in the
“Operation” section of the User manual.
•
Light the Pilot Burner.
•
Light the Main Burner.
•
Turning 'Off' the Main Burner / Pilot.
Ensure that the operator has been instructed in the areas of correct lighting, operation, and
shutdown procedure for the appliance.
The User manual must be kept by the owner for future reference and a record of the
Date of
Purchase, Date of Installation and the Serial Number of the Appliance must be recorded and kept
with the manual. (These details can be found on the Rating Plate, refer to the ‘Dimensions’
section for the locations of the Rating Plate for different applications. Also refer to the ‘Gas
Connection’ section).
NOTE: If for some reason it is not possible to get the appliance to operate correctly, shut off the
gas supply and contact the supplier of this appliance.
WARNING:
D
O
NOT
USE
A
NAKED
FLAME
TO
CHECK
FOR
GAS
LEAKAGES
.
For the Refrigeration Cabinet Installation refer to the Refrigeration Cabinet Installation and
Operation Manual supplied with the appliance.
Burner Operating Pressure
Test Point (Outlet)
Fig 2