![Blue Seal GP51 Service Manual Download Page 24](http://html.mh-extra.com/html/blue-seal/gp51/gp51_service-manual_2776503024.webp)
6
Service Procedures
20
© Moffat Ltd, January 2007
Revision 1/
Blue Seal Evolution Series Gas Griddles
6.2.2 Griddle Burner Injector
1) Remove the griddle plate control panel (refer
section 6.1.1).
2) Unscrew the griddle burner injector from its
mounting bracket.
3) Clean or replace as necessary and reassemble
in reverse order.
Figure 6.2.2
Injector
6.2.3 Pilot Burner
1) Remove the griddle plate control panel (refer
section 6.1.1).
2) Disconnect the piezo electrode, thermocouple,
and pilot supply tube from the pilot burner
assembly.
3) Undo the two screws securing the pilot burner
to the burner box.
4) Withdraw the pilot burner and replace.
Reassemble in reverse order.
Figure 6.2.3
Figure 6.2.1c
7) The burner can now be withdrawn from the
unit. Replace and reassemble in reverse or-
der.
Note: When reassembling, it is important that
the thermostat phials are correctly located.
These should be pushed fully into the block
on the underside of the griddle plate. A small
hole in the burner box panel indicated the
approximate position of the thermostat phial
block.
Figure 6.2.1d