4
Specifications
Gas Supply Requirements
- Australia:
- New Zealand:
- UK Only:
NOTE: * Measure burner operating pressure at manifold test point with both burners operating at
full setting. Operating pressure is ex-factory set and not to be adjusted, apart from when
converting between gases, if required. (Refer to ‘Gas Conversion’ section for details).
Natural (G20)
Propane (G31)
Heat Input (Gross)
Nominal
8.8 kW
8.8 kW
Reduced
3.6 kW
2.6 kW
Gas Rate
Nominal
0.84 m
3
/hr 0.63
kg/hr
Reduced
0.34 m
3
/hr 0.19
kg/hr
Supply Pressure
20 mbar
37 mbar
Burner Operating Pressure
10 mbar (*)
26 mbar (*)
Gas Connection
1
/
2
” BSP Male
Natural Gas
LP Gas (Propane)
Input Rating (N.H.G.C.)
31.5 MJ/hr
31.5 MJ/hr
Supply Pressure
1.13 - 3.4 kPa
2.75 - 4.5 kPa
Burner Operating Pressure
1.0 kPa (*)
2.55 kPa (*)
Gas Connection
½" BSP Male
Natural Gas
LP Gas
Input Rating (N.H.G.C.)
31.5 MJ/hr
31.5 MJ/hr
Supply Pressure
1.13 - 3.4 kPa
2.75 - 4.5 kPa
Burner Operating Pressure
1.0 kPa (*)
2.55 kPa (*)
Gas Connection
½" BSP Male