10
Installation
NOTE: It is important that adequately sized piping runs directly to the connection joint on the
appliance with as few tees and elbows as possible to give maximum supply volume.
3.
Fit the gas regulator supplied, into the gas supply line as close to the appliance as possible.
For G592 the regulator connection is ½" BSP female. The connection on the unit is ½" BSP male.
For G594 / G596 / G598 the regulator connections are ¾" BSP female. The connection on the
unit is ¾" BSP male.
(Refer to the ‘Specifications’ section for the gas supply location dimensions).
NOTE: The gas pressure regulator provided with this appliance is convertible between Natural
Gas and LPG as per the ‘Gas Conversion Section’ in this manual.
Ensure the regulator is converted to the correct gas type that the appliance will
operate on.
The regulator outlet pressure is fixed ex-factory for the gas type that the
regulator is converted to and it is NOT to be adjusted.
4.
A suitable joining compound which resists the breakdown action of LPG must be used on every gas
line connection, unless compression fittings are used.
NOTE: A manual isolation valve must be fitted to the individual appliance supply line.
5.
Correctly locate the appliance into its final operating position and using a spirit level, adjust the legs
so that the unit is level and at the correct height.
6.
Connect the gas supply to the appliance.
7.
Check gas operating pressure is as shown in ‘Specifications’ section.
8.
Check all gas connections for leakages using soapy water or other gas detecting equipment.
NOTE: The operating pressure to be measured at the
manifold test point and with two burners
operating at the ‘High Flame’ setting. (With
the exception of the G592 model which has
one burner only).
9.
Turn off the mains gas supply and bleed the gas out of
the appliance gas lines.
10. Turn ‘ON’ the gas supply and the appliance.
11. Verify the operating pressure remains correct.
Commissioning
1.
Before leaving the new installation;
a. Check the following functions in accordance with the operating instructions specified in the
‘Operation’ section of this manual.
•
Light the Pilot Burner.
•
Light the Main Burner.
•
Check the Low Fire Burner Operation.
•
Check the High Fire Burner Operation.
b. Ensure that the operator has been instructed in the areas of correct lighting, operation, and
shutdown procedure for the appliance.
2.
This manual must be kept by the owner for future reference and a record of
Date of Purchase
,
Date of Installation
and
Serial Number of Unit
recorded and kept with this manual.
(These
details can be found on the rating plate attached to the underside of the R/H side, front
hob lower trim. (Refer to the ‘Gas Connection’ section).
NOTE: If for some reason it is not possible to get the appliance to operate correctly, contact
the suppler of this appliance.
WARNING:
CHECK CONNECTIONS FOR LEAKS WITH SOAPY WATER. DO NOT USE A NAKED FLAME.
Fig 3
Manifold
Test Point
Summary of Contents for Evolution G592
Page 8: ...6 Dimensions G594 LS G596 LS G598 LS R Rating Plate Location for this option R ...
Page 27: ...25 Replacement Parts Chargrill 300mm Main Assembly ...
Page 29: ...27 Replacement Parts Chargrill 300mm Gas System Assembly ...
Page 31: ...29 Replacement Parts Chargrill 600mm 900mm 1200mm Main Assembly Bench Mount Option ...
Page 33: ...31 Replacement Parts Chargrill 600mm 900mm 1200mm Gas System Assembly ...
Page 35: ......