23
Gas Conversion and Specifications
Gas Specifications
(*) NOTE:
•
The burner operating pressure is to be measured at the manifold test point with one
burner for G592 Model or two burners for other models operating at full setting.
•
NAT, LPG & Butane Only - The operating pressure is ex-factory set and is not to be
adjusted, apart from when converting between gasses, if required.
•
TOWN GAS Only - The burner operating pressure is to be adjusted using the
adjustable gas regulator supplied.
•
Refer to the ‘Gas Conversion and Specifications' section of this manual for further
details.
Natural Gas
LPG
Butane
Town Gas
G592
G594
G596
G598
G592
G594
G596
G598
G592
G594
G596
G598
G592
G594
G596
G598
Main Burner
Ø
2.70mm
Ø
1.65mm
Ø
1.55mm
Ø
4.50mm
Pilot Burner
0.35
0.45
0.25
0.30
0.25
0.30
0.60
0.75
Low Fire
Adjustment
1
1
/
4
turns out (ccw)
½ turn out (ccw)
2 turns out (ccw)
Burner Aeration
Setting
Fully Open
Fully Open
Fully Open
Supply Pressure
1.13 - 3.40 kPa
(4.5” - 13.5” w.c.)
2.75 - 4.50 kPa
(11” - 18.0” w.c.)
0.75 - 1.50 kPa
(3” - 6” w.c.)
Burner Operating
Pressure (*)
1.00 kPa
0.95 kPa
2.5 kPa
2.6 kPa
2.5 kPa
2.6 kPa
0.63 kPa
Gas Regulator
Cap Screw
Adjustable Regulator
(Adjust to the Burner
Operating Pressure
specified)
Summary of Contents for Evolution G592
Page 8: ...6 Dimensions G594 LS G596 LS G598 LS R Rating Plate Location for this option R ...
Page 27: ...25 Replacement Parts Chargrill 300mm Main Assembly ...
Page 29: ...27 Replacement Parts Chargrill 300mm Gas System Assembly ...
Page 31: ...29 Replacement Parts Chargrill 600mm 900mm 1200mm Main Assembly Bench Mount Option ...
Page 33: ...31 Replacement Parts Chargrill 600mm 900mm 1200mm Gas System Assembly ...
Page 35: ......