-6-
It is most important that the oven is installed correctly and that the operation is correct
before use. Installation must comply with local gas, electrical, health and safety
requirements.
BEFORE CONNECTION
Unpack oven and check for damage. Report any damage to the carrier and dealer.
Report any deficiencies to your dealer.
To Fit Legs - Single Unit
Tilt the oven over on one side and fit both the front and rear legs to the side now off
the ground. Fit them into the base frame under the chassis base and secure to the
base with the bolts, spring washers and flat washers provided. Lift up the other side
of the oven, fit legs, bolts and washers, but do not tighten yet. Position leg tray (flat
side facing up) between legs and secure with 4 screws provided, then tighten all leg
bolts. Level the oven by adjusting the feet.
To Fit Legs - Double Unit
Fit and secure 4 short legs onto the bottom unit by the method described above.
NOTE: There is no leg tray for the double unit. Lay the top unit on its side and fit the
spacers provided to the base of the oven.
Lift the top unit onto the bottom unit and secure around the spacer panel flanges with
self-tapping screws provided. Fit chimneys over the duct assembly of the bottom
unit. Screw in place and pull down chimney surrounds onto the duct assembly.
Level the oven by adjusting the feet.
ELECTRICAL CONNECTION
This E1100 convection oven can be supplied as single or twin deck unit and are to be
connected to a 400 - 415V A.C. 3 phase, neutral and earth supply. Refer to the
rating plate for loading per phase.
The mains terminal block is positioned at the left rear of the unit. Access is provided
by a detachable panel on the back panel. Each oven should be connected to a circuit
breaker (or switch and fuses). These should be mounted on the wall adjacent to the
oven and should be readily accessible and clearly marked.
Bring the connecting cable up through the base panel and tighten the conductor
strands securely to the terminal block studs. The earth screw is located in the base
panel next to the cable entry hole.
WARNING - THIS APPLIANCE MUST BE EARTHED
IMPORTANT - FIXED WIRING INSTALLATIONS MUST INCORPORATE AN ALL-
POLE
DISCONNECTION
SWITCH.
IF SUPPLY CORD IS DAMAGED, IT MUST BE REPLACED BY A SUITABLY
QUALIFIED PERSON IN ORDER TO AVOID A HAZARD.