![Blue Sea Systems Battery LINK 7606 User Manual Download Page 9](http://html.mh-extra.com/html/blue-sea-systems/battery-link-7606/battery-link-7606_user-manual_2776289009.webp)
Specifications are subject to change. See bluesea.com/products/7606 for current information.
8
FULL INSTALLATION DIAGRAM
start
run
accessory
off
START KEY SWITCH
NEGA
TIVE
STUD
POSITIV
E
STUD
S
OPTIONAL
START ISOLATION
(SI) WIRE
OPTIONAL
BATTERY
TEMPERATURE
SENSOR
Legend
Ground
OPTIONAL
REMOTE
INDICATOR
Optional
DC Negative
DC Positive
AC INPUT
BatteryLink™ Charger 20A
MULTISTAGE CHARGER
INTEGRATED ACR
2A FUSE
16 AWG
(1.5mm²)
FUSE*
2A FUSE
16 AWG
(1.5mm²)
FUSE*
FUSE*
NEGATIVE
BUS BAR
ACCESSORIES
AUXILIARY
BATTERY
START
BATTERY
2A FUSE
16 AWG
(1.5mm²)
FUSE**
7606
AC
AC Connections
Line: Brown
Neutral: Blue
Ground: Green/Yellow
DC SAFETY
GROUND***
OPTIONAL
COMBINE
SWITCH
(sold separately)
YELLOW WIRE
RED WIRE
ENGINE
* See Wire Size and Fuse Rating Table, page 5.
** Wire size and fuse rating based on house loads. For more information, use the Circuit Wizard at circuitwizard.bluesea.com.
*** DC safety ground wire must be no more than one nominal wire size smaller than the positive battery wires. If the rating of the circuit
protection used in the positive battery wires is greater than 135% of the ampacity of the smaller proposed DC safety ground wire,
then the DC safety ground wire must be the same size as the positive battery wires.