![Blue Sea Systems Battery LINK 7606 User Manual Download Page 11](http://html.mh-extra.com/html/blue-sea-systems/battery-link-7606/battery-link-7606_user-manual_2776289011.webp)
Specifications are subject to change. See bluesea.com/products/7606 for current information.
10
Specifications
Nominal Output Voltage
12V DC
Total Output Current
20A DC
Output Connections
2 positive, 1 negative
Universal AC Input Voltage
100V-240V AC
Input Frequency Range
50/60 Hz
AC Input Current
4.0A @ 100V
1.8A @ 200V
Typical Float Voltage (25°C)
13.5V DC
Typical Absorption Voltage (25°C)
14.4V DC
Reduced Output (battery temp 45°C to 49°C)
4A DC / Limited to Float Voltage
Battery Temperature Compensation Coefficient
-30 mV/°C (maximum offset
±
0.88V)
ACR Continuous Rating
170A
ACR Continuous Rating (during AC charging)
80A
ACR Cranking Rating (30 sec.)
300A
ACR Combine Voltage
13.0V (2 min.)
13.5V (30 sec.)
ACR Open Voltage
12.75V (10 sec.)
12.35V if voltage is rising
ACR Manual Combine Timeout
10 minutes
Operating Current (no AC power)
10mA
Negative Terminal Stud Size
1/4"-20 (accepts M6 ring terminal)
Maximum 1/4
”
Terminal Stud Torque
60 in-lb (6.8 Nm)
Positive Terminal Stud Size
3/8
"
-16 (accepts M10 ring terminal)
Maximum 3/8
”
Terminal Stud Torque
140 in-lb (15.8 Nm)
Quick Connect Terminal Size
1/4
"
x 0.032
"
Operating Temperature Range
-20°C to 35°C at full power
Storage Temperature Range
-30°C to 80°C
Warranty
5 Year
Battery Types
Flooded, AGM, TPPL
Battery Number of Cells
6 cells
Recommended Maximum Battery Capacity 400Ah (20h rate), Total of both banks
Recommended Minimum Battery Capacity 100Ah (20h rate), Per bank
Regulatory
CE Certified, Designed and constructed for compliance to EN60335-2-29.
Ignition protected per ISO 8846 and SAE J1171.
Waterproof IP67 (excluding terminations)