Product Manual
Tel: +0086-023-86850812
Email:[email protected]
Fax:+0086-023-67636974
Add: Building 13, 2-8, Jialing third village Pioneer Park, Jiangbei District, Chongqing
- 6 -
7. - EMC Test
standard
Test voltage
Electrostatic discharge immunity
test:
IEC-61000-4-2
level 4
8Kv
Electrical fast transient burst
immunity test
IEC61000-4-4
level 3
Input 1kV; Power supply 2kV
Surge (Shock) immunity test
IEC61000-4-5
level 4
common mode test voltage
4kV
8. - Work environment
Temperature: -20
℃
~ +60
℃
Humidity: RH 20%
~
95%
(
No condensation
)
9. - Protection
Panel: IP54
Case: IP20
10. - Storage Conditions
Temperature: -25
℃
~
+70
℃
Humidity: RH 20%
~
95%
11. - Working Power
AC 80-265V, 45-65Hz, DC 80-380V
DC 20-60V (Optional)
Maximum power consumption 6W
12. - Dimensions
L × W × H =72mm×72mm×71mm
13. - Installation hole size
L × W = (66+0.8mm) × (66+0.8mm)