Blue by ADT S40LR0-01 Setup Manual Download Page 13

13 

8/7/2020 

 

to follow your manufacturer’s instructions to put the device into inclusion mode. Once the device 
is added you will hear a confirmation beep from your smart home hub and you will be brought to 
a screen to name the device and to choose an icon. 
 
Some Z-Wave devices may support secure adding also known as ‘S2.’ S2 devices encrypt their 
communication with the smart home hub for added security. These devices can be added using 
the process described above, but once the device has been discovered, you will be prompted to 
enter a PIN code provided on the device label to complete the process. After the device has been 
successfully added, it will operate like any other Z-Wave device. If secure add fails, the device 
may still add, but in an unsecured mode, and you may be prompted to delete and reinstall the 
device to ensure it is properly secured. 
 

Note: Not all Z-Wave device types may be supported by the system. If you choose to add a device 
that is unsupported, it will come into the system as unknown and be located in the lights and 
appliances cards.  
 
Controlling a device: 

Once a Z-Wave device has been added to the Blue Smart Home Hub, it can be controlled using 
the home automation cards on the main screen of the iOS, Android, or web applications. All 
devices can be issued basic on/off commands, but devices which support other features will have 
additional control options on their card. 
 
 
 

Lights 

Turn the light on and off and change the brightness for dimmable switches. 

Locks 

Lock and unlock the lock. 

Garage doors 

Open and close your garage door. 

Thermostats 

View your current temperature and mode, adjust your temperature settings, 
change the heating and cooling mode, and change the fan mode. 

Unknown 
devices 

Any device that is added to the system but is not recognized as a fully 
supported device will only have basic on/off control. 

  

Sensors: 

The system does not currently support Z-Wave sensors. It is recommended that you use 
DECT/ULE sensors that can be purchased in the Blue by ADT store instead.  
 

Association Group information: 

This product supports Association Group 1 (Lifeline) with the maximum of 5 nodes. This 
product will send CC DEVICE_RESET_LOCALLY to the lifeline before performing default 
factory reset. 

 
Removing a device: 

To remove a device, go to Settings > Devices and choose your device. You can then delete it by 
clicking remove and following your manufacturer’s directions to put the device into exclusion 
mode. If a device is not on the network, you may fail the remove and then be prompted to 
remove the failed device. This will remove the device from the network without it being present. 

Summary of Contents for S40LR0-01

Page 1: ...1 8 7 2020 Blue by ADT security system setup guide Blue Smart Home Hub Part number MAN4000 Revision 1 1...

Page 2: ...reless Blue by ADT Keychain Remote SKF3R0 29 26 4 5 Blue by ADT Motion Sensor SSM1R0 29 30 4 6 Adding the SSS1R0 29 Blue by ADT Smoke Detector 32 4 7 Adding the SSW1R0 29 Blue by ADT Flood Temperature...

Page 3: ...ecked by a qualified technician at least every 3 years This equipment should be installed in accordance with chapter 29 of the National Fire Alarm Code ANSI NFPA 72 National Fire Protection Associatio...

Page 4: ...hen installed on an open joisted ceiling the smoke alarm should be placed on the bottom of the joists The smoke alarm should be positioned relative to the stairway so as to intercept smoke coming from...

Page 5: ...2 sensors to trigger or a visually verified intrusion before they will dispatch police A sensor on an opened door combined with motion detection satisfies this requirement In addition to cost and dama...

Page 6: ...0 29 Blue Flood Temperature Sensor SKP3R0 Blue Keypad SKF3R0 29 Blue Keychain Remote 3 1 Maximum components per system Smart home hub 1 Keypad 250 Door window sensors 250 Motion sensors 250 Smoke dete...

Page 7: ...er Please see the notes below on Wi Fi signal coverage in a home If you intend to use the LTE cellular capability of the smart home hub the device will need to receive a cellular signal In most parts...

Page 8: ...it interrupter GFCI that could switch power off Insert the power adapter plug fully into the jack on the bottom of the smart home hub Plug the power adapter into the wall outlet Place the power adapte...

Page 9: ...customer service representative has instructed you to press the button Arming your security system Blue by ADT provides a variety of options for arming and disarming your system The Blue by ADT Smart...

Page 10: ...ows for multiple User Codes which will enable you to keep track of who arms and disarms your system Master User Code You will only have one 4 digit Master User Code which gives you complete access to...

Page 11: ...econdary contact and any courtesy contact until someone has the correct monitoring passcode If the incorrect monitoring passcode is provided or no contact can be reached the monitoring center will con...

Page 12: ...you can add a device by selecting and then either selecting Manually or Scan QR Code and follow the prompts Once a SmartStart device has been successfully added its DSK Device Specific Key and status...

Page 13: ...main screen of the iOS Android or web applications All devices can be issued basic on off commands but devices which support other features will have additional control options on their card Lights Tu...

Page 14: ...k for that device Adding your smart home hub to another network If you would like to add the smart home hub into another Z Wave network you must first delete all Z Wave devices from the smart home hub...

Page 15: ...Functional overview This device behaves as static controller based on the Z Wave Controller Library It controls devices using the following Z Wave Command Classes Ver sion Non secured CC Ver sion Secu...

Page 16: ...at operating mode COMMAND_CLASS_THERMOSTAT_OPERATING_STATE To display thermostats status Add a thermostat On the User App change the thermostat operating mode See that the operating state is displayin...

Page 17: ...home hub troubleshooting Slash LED light Smart home hub status What you should do The light on the top of the smart home hub is flashing or alternating yellow red The smart home hub is trying to conne...

Page 18: ...do not close the door completely when leaving your home during exit delay The entry delay time will start immediately giving you the chance to disarm the system before an alarm is sent to the monitor...

Page 19: ...e is no action required on your part The S40LRBR0 01 battery typically has a chemical life of at least 5 years If this battery requires replacement use only Blue by ADT Rechargeable Battery supplied w...

Page 20: ...ght may operate continuously When the keypad is operating from only battery power the display and backlight will only operate while in use i e while pressing keys and for 20 seconds thereafter Before...

Page 21: ...y ADT Keypad should be located by an entrance in your home like your front door or garage door The keypad can either be mounted onto the wall or placed on a tabletop The keypad should be within earsho...

Page 22: ...n enter your User Code to arm in away mode o Use this mode when no one s home entry and exit delays are on and motion sensors are on NIGHT Press the night button and then enter your User Code to arm i...

Page 23: ...delay exit delay Flashing red Alarm panic Flashing green Disarmed not ready to arm Flashing yellow A device is faulted lost or has a low battery Flashing blue Boot mode device is restarting White blue...

Page 24: ...municate with To pair your sensors with the Blue Smart Home Hub just launch your Blue by ADT app Once logged in select Menu Devices Add Device Sensors Door Window Sensor and follow the in app setup he...

Page 25: ...ed double sided tape to mount the magnet Make sure the alignment marks circles of both the sensor and magnet are facing each other Remove the tape liner and press firmly in place for 30 seconds Note T...

Page 26: ...sing 4 Verify operation after replacing the cover Warning the polarity of the battery must be observed Improper handling of lithium batteries may result in heat generation explosion or fire which may...

Page 27: ...t police dispatch automatically to the monitoring location of your system Installation 1 Slide the back cover off to reveal the battery with its activation tab 2 Pull out the activation tab to engage...

Page 28: ...fficient if the keychain remote is used within 30 to 50 yards of the smart home hub To prevent accidental transmissions such as while in a pocket or purse the keychain remote will ignore all key press...

Page 29: ...hing blue ENTRY or EXIT DELAY Flashing red ALARMED EXIT ALARM or PANIC Batteries Replace only with a CR2450 battery 3 0 V 620 mAh The recommended brand is Murata The Blue Keychain Remote will detect a...

Page 30: ...ce logged in select Menu Devices Add Device Sensors Motion Sensor and follow the in app setup help to pair your sensor Note Sensors and devices in a Blue by ADT system are preconfigured so they will b...

Page 31: ...e 2 Remove the backing and press and hold the device to the wall for 30 seconds To mount the sensor using screws remove the rear cover and use the supplied screws and anchors to mount the rear cover t...

Page 32: ...ifornia only The Perchlorate warning only applies to Manganese Dioxide Lithium batteries sold or distributed in ONLY in California USA Perchlorate Material special handling may apply See www dtsc ca g...

Page 33: ...xhaust near furnaces hot water heaters and space heaters Do not install smoke detectors less than 20 ft 6 m away from places where combustion particles are normally present like kitchens If a 20 foot...

Page 34: ...for a few seconds after you release the button If it does not alarm make sure the smoke detector s battery is installed and test it again If it still does not alarm replace it immediately During testi...

Page 35: ...tor s alarm sound or to help those who may be incapable of safely evacuating the area unassisted The smoke detector s alarm has a limited lifespan Although this smoke detector has passed many tests an...

Page 36: ...om of the unit Place the sensor on the ground in the area to be monitored with the probes facing downward Wall mounting For wall mounting the sensor must use the external extension probe 1 Remove the...

Page 37: ...tery with a CR123A battery only 5 0 Settings The Blue by ADT application presents a menu for accessing the Settings of the system Swipe to reach Settings icon enter the Master Code and select the devi...

Page 38: ...ience Entry Delay 30 sec 45 sec 60 sec 90 sec 2 min 4 min Chime Enabled Yes No Cross Zoning Yes No Swinger Shutdown Yes No Abort Window Time Yes No Blue Smoke Detector Name 16 character limit Alphanum...

Page 39: ...Exit Time Restart The system includes an option whereby during Exit Time if a sensor trips restores and then trips again prior to the end of Exit Time the Exit Time will restart This might occur for e...

Page 40: ...nd cancelling alarm Abort Window After Entry Delay expires the local Alarm will sound However the system provides an additional delay known as Abort Window before the Alarm is sent to the monitoring c...

Page 41: ...system includes an operating mode whereby the system ignores a sensor if that sensor repeatedly trips after a limited number of trips This might occur if a door or window was not completely shut and...

Page 42: ...has expired NOTE If a door doesn t open and close during the Exit Delay the system will automatically switch the arming mode to STAY Not available on the keypad Enter your Code Press and hold Police...

Page 43: ...ower low battery lost sensor or no internet the system will display flashing yellow LED on the smart home hub The system will also emit a unique tone Use the Blue by ADT app to view the Trouble Condit...

Page 44: ...t 1 week of warning to replace a low battery Replace batteries using the model numbers from the table below Device Battery model number Brand Smart home hub S40LRBR0 01 3 7 volts 2400 mAh nominal Blue...

Page 45: ...to No on Blue by ADT com AWAY Leaving Home Arm AWAY when leaving your home All sensors are monitored except those designated as a Non Monitored Type An audible Exit Delay and Entry Delay is supported...

Page 46: ...ored Blue Keychain Remote A Blue Keychain Remote allows you to arm your security system from outside your home Master Code One Master Code is supported which you entered as part of your activation pro...

Page 47: ...attached to a door or window while the sensor is attached to a door or window frame STAY Arm Stay while you are at home A silent Exit Delay and an audible Entry Delay is supported User Codes User Code...

Page 48: ...emergency release devices inside so that they can be opened immediately in an emergency Emergency release devices won t compromise your security but they will increase your chances of safely escaping...

Page 49: ...exit Closing doors on your way out slows the spread of fire giving you more time to safely escape In some cases smoke or fire may prevent you from exiting your home or apartment building To prepare f...

Page 50: ...about fires caused by carelessness and safety hazards like smoking in bed violent explosions escaping gas improper storage of flammable materials overloaded electrical circuits children playing with...

Page 51: ...inadequate maintenance This security system should be tested weekly including any smoke detectors to make sure all sensors and transmitters are working properly Wireless transmitters are designed to p...

Page 52: ...the following measures Reorient or relocate the radio or television receiving antenna Reorient or relocate and increase the separation between the Blue by ADT equipment and radio or television receive...