3
www.blueangelpumps.com
sensor is 180° away from the inlet.
Make certain the incoming water
stream does not hit the surface (See
Figure 3B).
8. When a tether switch is used, rigid
dis charge pipe is required. If the
pump is allowed to move, the
tether switch could be re strict ed
by the basin wall, pre vent ing the
pump from operating.
Before removing
pump from basin
for service, always disconnect electrical
power to pump and control switch. For
any work on pump or switch, ALWAYS
unplug the power cord. Do not just turn
off circuit break er or unscrew fuse.
Maintenance
Make certain that
the pump is
unplugged before attempting to service
or remove any component. This pump is
assembled in the factory using special
equipment; therefore only authorized
service dealers or qualified electricians
should attempt to repair this unit.
Improper repair can cause an electrical
shock hazard.
The pump contains
oil that may be
under pressure because of heat. Let the
pump cool for a minimum of two hours
before servicing this unit.
1. Disassembly of the motor prior to
expiration of war ran ty will void the
warranty. It might also cause internal
leakage and damage to the unit. If
repairs are required, return the pump
to the dealer from whom it was
pur chased or call 1-888-636-6628. If
motor is ever disassembled the o-rings
must be replaced. Care must be taken
to ensure that all seals do not leak.
2. After the basin cover is removed
and necessary dis charge piping
disconnected, lift pump from basin.
3. Pump should be checked on a
regular basis for proper op er a-
tion. If anything has changed since
unit was new, the unit should be
removed and repaired or replaced.
Only qualified electricians or service
peo ple should at tempt to repair
this unit. Improper repair and/or
assembly can cause an electrical
shock hazard.
4. Place the pump in a suitable area
where it can be cleaned thoroughly.
Remove all scale and deposits on pump.
5. Submerge the complete pump in a
disinfectant so lu tion (10% chlorine
bleach solution) for at least one
hour before handling the pump.
6. Clean all dirt and deposits from the
pump float. Make sure float moves
freely after cleaning.
7. Clean all dirt and deposits away
from pump inlet and volute
8. Clean water sensor surface (model
BCAPSE40).
This pump contains
dielectric motor
oil for lubrication and motor heat
transfer. This oil can be harmful to the
environment. Check state environmental
laws before disposing of this oil. This
oil can be harmful to aquatic life so
consideration should be exercised in the
application of this pump.
Check valve 45º
Vent
Inlet
Gasket
1/2 inch
Min.
Clearance
Basin
figure 3A - Prefabricated Basins
Check
valve 45º
Vent
Inlet
Gasket
*Orient the pump
so that the sensor is
180° away from the
inlet. Make sure the
incoming water stream
does not hit the sensor
surface.
Basin
figure 3B - Prefabricated Basins
figure 2 - Typical Installation
Upper level
drainage
Switch
2 inch
Check
Valve
45º Elbow
Washer
Dryer
Floor drain
Washer drain
Flange
Cleanout
Laundry tubs
Lavatory
Shower
Toilet
Vent pipe
Vent pipe
Sewage pump passes
2 inch dia. solids
Three prong grounded outlet equipped
with a ground fault interruptor
2 inch
Gate Valve
2 inch Discharge pipe
General Safety
Information
(continued)
CSE40M, CSE40T
CSE40T-2 and BCAPSE40