background image

PROGRAMMING (continued)  

15 

Brew Volume 

The 1st key is the Standard 
Brew Volume. 
When a brew volume other 
than standard brew volume is 
selected, the Brewer will 
complete that brew then return 
to the standard brew volume 
automatically. 
 

7.    Automatic Start-Up in Previous Mode: 

 

       If the Satellite Brewer automatic timer is OFF (the factory  
       setting) and power is disconnected, the brewer will start up 
       when power is restored, in the mode it had been in prior to 
       the power disconnection.   If the Satellite Brewer has the 
       timer setting ON and power is disconnected, the brewer will 
       start up in the mode that it should be in at the time the power 
       is restored. 

 
8.    Brew Volume:

  

       The Brewer can have up to 3 different brew volumes on each 
       side.  When a volume other than the standard, or first brew 
       volume, is selected, the Brewer will complete that volume 
       and then automatically reset to the standard, or first brew
       volume. 
       To view, press the individual volume key.  The brew volume 
       will be displayed on the screen for 3 seconds.  If there is 
       no brew volume for a specific key, the screen will read “

no 

       volume prog

”, (i.e. no volume programmed). 

        

  9.  Clock 
       Time – Battery Backup.

  The Satellite Brewer has a battery 

       backup system which will maintain the proper time during 
       power failures, or when the brewer is unplugged (even for 
       very prolonged periods of time).  Normally there will not be a 
       need to set the time except for Daylight Saving Time 
       changes, or moving the brewer to different time zones.  
 

10.  Changing Day and Time: 

 To change time, in the OFF 

       mode, press the 

2nd key 

twice followed by the 

1st key 

twice 

       to access the time change mode.  In the time change mode 
       he screen will read “

Day:

” followed by the current day 

       setting.  Use the 

6th key 

to advance the day, or the 

5th key  

       

to reverse. 

 
       When day has been properly set, press the 

3rd key

.  The 

       screen will now read “

Time:

 

with the set time on the screen, 

       the 

hour and am or pm 

flashing.  Use the 

6th key 

to advance 

       the hour, or the 

5th key 

to reverse,  making sure that the am 

       or pm is correct. 
 
       When the hour and am/pm is correctly set, press the 

3rd key

       and the screen will read “

Time:

 

with the set time on the 

       screen, 

minutes

 flashing.  As previously, use the 

5th 

or

 6th 

       

keys

 to adjust the minutes, and press the 

3rd key 

when 

       complete.  The Brewer will return to the off mode.  (Changing 
       time can also be done in the regular programming mode.) 

Summary of Contents for 9421 (SS2-HE)

Page 1: ...569 www wellsbloomfield com p n 74340 Rev C M673 040402 cps 673 OWNERS MANUAL for SS2 SERIES DUAL SATELLITE COFFEE BREWERS with ELECTRONIC PROGRAMMABLE CONTROL and EXTERNALLY HEATED SATELLITE SERVERS...

Page 2: ...f its sub agencies This service will be provided on customer s premises for non portable models Portable models a device with a cord and plug must be taken or shipped to the closest Authorized Service...

Page 3: ...d maintain or repair the appliance in a manner which will ensure its optimum performance WARRANTY STATEMENT xi SPECIFICATIONS 1 FEATURES OPERATING CONTROLS 2 PRECAUTIONS GENERAL INFORMATION 4 AGENCY A...

Page 4: ...FEATURES AND OPERATING CONTROLS 2 Fig 1 SS 2 Satellite Brewing System Features Operating Controls...

Page 5: ...dispensed here Lists manufacturer model and serial number Also lists voltage and wattage rating of brewer Controls brewer ON MODE and OFF MODE Located on lower right rear of brewer Turns main power to...

Page 6: ...r wiring Any procedure which requires the use of tools must be performed by a qualified technician This manual is considered to be a permanent part of the appliance This manual and all supplied instru...

Page 7: ...ss than 3 8 copper tubing for installations exceeding 12 Brewer should be connected to a COLD water line NOTE DO NOT use a saddle tap for this water line connection A shut off valve must be installed...

Page 8: ...applied to the brewer the display will read BLOOMFIELD briefly and a beep will sound Press the POWER key The inlet valve will energize and the tank will begin filling The display will read Filling Fil...

Page 9: ...ly installed inside the spray heads Check the brew chambers Check that the brew chamber is clean Check that the wire basket is properly installed in the brew chamber DAILY START UP Press system switch...

Page 10: ...brew head Insert Satellites Slide one satellite under each brew chamber until it is fully seated Press appropriate WARMER SWITCH to ON SATELLITE LED for left or right side will glow Select Brew Volume...

Page 11: ...ee from the brew water tube and is controlled by a signal from the CONTROL BOARD The bypass valve is opened for a length of time as determined from programmed values The bypass valve discharges throug...

Page 12: ...ve and empty brew baskets 4 Remove spray disks and gaskets from spray heads 5 Wipe inside of spray head and area around spray head with a soft clean cloth or sponge moistened with clean water 6 Wash s...

Page 13: ...rd Then pull ears forward Lift guard off of retaining clip b Remove sight glass tube from silicone elbow Run the sight glass brush through the tube at least ten times c Reassemble the tube to the sili...

Page 14: ...key Clock Settings Press POWER key to enter ON mode Press 3rd 4th keys at the same time Check Tank Temperature Press POWER key to enter ON mode Press 3rd 6th keys at the same time NOTE Time is held in...

Page 15: ...d immediately after a brew has been completed notably on 120v models If the tank temperature is below the brew temperature the brew will be delayed going into the Brew Wait mode with the brew light fl...

Page 16: ...e automatic timer turned off To set the automatic timer refer to Time Functions Menu If the Automatic Timer feature is programmed off the brewer can be turned on and off by pressing the POWER key as n...

Page 17: ...ead no volume prog i e no volume programmed 9 Clock Time Battery Backup The Satellite Brewer has a battery backup system which will maintain the proper time during power failures or when the brewer is...

Page 18: ...s If a particular brew volume has utilized the pulse or pre infusion option that volume will be displayed with an asterisk after the volume As an example Volume 2 would indicate that the second progra...

Page 19: ...Heats slow Connected to wrong voltage Verify supply voltage Scale build up on heating elements De lime hot water tank Damaged heating element Replace element Slow to fill Insufficient water pressure B...

Page 20: ...op panel then remove the tank lid assembly Do not disconnect the tank assembly at this time 3 Siphon all water from the hot water tank 4 Mix 10 gallons of deliming solution according to the manufactur...

Page 21: ...spray disks 13 Reconnect brewer to electrical supply 14 Install the brew chamber without filter paper or grounds 15 Place an empty satellite under the brew chamber Run at least five 1 1 2 gallon brew...

Page 22: ...EXPLODED VIEW CABINET AND EXTERIOR COMPONENTS 20...

Page 23: ...21...

Page 24: ...EXPLODED VIEW INTERIOR COMPONENTS 22 26 32 38 39 36 33 3 41 1 14 30 29 21 19 16 17 47 18 5 8 6 7 37 42 43 45 31 3 9 15 40 48 49 30 34 46 10 34 50 13 4 27 3 28 24 22 44 12 25 27 20 35 11 2 23 29...

Page 25: ...A 2 23 83319 PLUG TANK LID 298 DIA 1 24 83320 PLUG TANK LID 687 DIA 1 25 83325 TANK LID ASSY 1 26 84336 TUBE TANK TO TEE 2 0 2 27 8043 11 ELBOW OUTLET 2 28 83384 TUBE VENT EXTENSION 2 29 83537 TUBE SI...

Page 26: ...24 WIRING DIAGRAM...

Page 27: ...4390 FAUCET MODEL ES 1 4 2 8700 25L SEAT CUP 3S10 1 4 3 84392 HANDLE 13SBE SNAP 1 4 4 84394 C RING 18 1 1 4 5 8600 26 NUT HEX 1 4 6 84395 SHANK 1 5 84299 HOUSING SIGHT GAUGE 1 6 84300 BRACKET SIGHT GA...

Page 28: ...Telephone 775 345 0444 Service 888 492 2782 website www wellsbloomfield com 5850 Keaton Cresent Mississauga Ontario Canada L5R 3K2 Telephone 905 507 1700 Fax 905 507 1777 Toll Free 877 507 1700 websi...