7
NOTE:
If water is not sensed at the
water level sensor within 20
minutes:
Heater will be disabled
Error message NO WATER
SENSED will be displayed
Call the PHONE NUMBER
displayed for service.
GETTING STARTED
Check the brewer and satellites:
Check that the brewer is clean and the drip tray (if used)
is empty.
Check that the satellites are empty and clean with lids
properly installed.
Check the spray heads:
Remove the brew chambers. Check the spray heads. Verify
that the spray disks are clean and properly installed. Verify
that the gaskets are properly installed inside the spray heads.
Check the brew chambers:
Check that the brew chamber is clean.
Check that the wire basket is properly installed in the
brew chamber.
DAILY START-UP
Press system switch (back of brewer, lower right corner) to ON:
Brewer will “beep” and briefly display the message
BLOOMFIELD.
Press POWER KEY to enter
ON
mode:
Brewer water tank will begin filling. The message FILLING
will be displayed.
When the tank is full, TANK HEAT LED will glow, and the
message HEATING is displayed indicating that the tank
heater is
ON
.
Press WARMER SWITCHES to
OFF
until you are ready to begin
a brew.
When the tank is filled and up to temperature, time and date are
displayed. The brewer is ready to operate.
OPERATING INSTRUCTIONS
Fig. 3 Control Panel
Summary of Contents for 9421 (SS2-HE)
Page 22: ...EXPLODED VIEW CABINET AND EXTERIOR COMPONENTS 20...
Page 23: ...21...
Page 26: ...24 WIRING DIAGRAM...