7
Clearview 4:2 SD
Quick Guide
Troubleshooting
For technical support please contact us at 1-800-523-6049 between the hours of 8am and 5pm EST.
Please refer to the User Manual for additional information.
Non-Standard Network Configuration
Example network configuration:
1.
The Video Source/Sink device's control port is configured to be at
192.168.3.18
.
2. The Clearview 4:2 SD
IP Video ports are configured to be at
192.168.6.71
-
192.168.6.82
(XC1
at “192.168.6.71”,
XC2 at
“192.168.6.72”, etc.) with subnet masks of
255.255.0.0
.
3.
The Management PC is configured to be at
192.168.3.5
with a subnet mask of
255.255.0.0
.
Note:
The subnet mask of the Video Source/Sink device must be configured to be on the same subnet mask as
the Management PC.
Accessing devices from the Management PC:
• To access the Video Source/Sink device, go to
http://192.168.3.18
• To access the Clearview 4:2 SD unit, go to
http://192.168.6.71
Note:
Additional
Clearview 4:2 SD units sharing the same network with a single Video Source/Sink device need
to have their transcoder (XC1 - XC12) IP addresses assigned to avoid collisions with XC IP addresses on other
Clearview 4:2 SD
units. In other words, all XC IP addresses on a network *
must
* be unique across all
Clearview
4:2 SD units.