Step 2: Connecting to a PC/Laptop

ETHERNET ACCESS:

Local or remote communication with the unit is only possible through a GUI-based menu via web browser (Chrome or Firefox 

is recommended)

. Before you can communicate with the unit, you must configure your computer's IP address to be in the 

same subnet as the units default IP address. To do so, follow these steps:

Connect one end of the Ethernet cable to the “

Control

” port on the unit front-panel interface. Connect the other end 

of the Ethernet cable to your computer.

The factory default IP address of the Control port is “

172.16.70.1

”. In order to communicate with the Control port, you 

must first change your computer's IP address.

1

2

The following steps explain how to do this for a computer with  

Windows 7

Windows 8.x

 or 

Windows 10

 operating software: 

(a) On your computer, navigate to the “Network and Sharing Center”.
     

 (Note: It can be found using the search box in the Start Menu or for Windows 8.x, the Start Screen)

(b) Once open, click on “Change Adapter Settings” on left hand side of the window.
(c) Right-click on the “Local Area Connection”, and then click on the “Properties”.
(d) A dialog box entitled “Local Area Connection Properties” will appear. In this box, double-click on the “Internet 

Protocol Version 4 (TCP/IPv4)”.

(e) A dialog box entitled “Internet Protocol Version 4 (TCP/IPv4) Properties” will appear. Select the “Use the following 

IP address” option and enter the following addresses:

IP address: 

172.16.70.2

Subnet mask: 

255.255.255.0

No need to enter a value for the Default Gateway.

Click OK to close the dialog box. Your computer is now ready to communicate with the unit.

IMPORTANT NOTE ON PORT CONFIGURATION

The “

Control

” port and “

IP Video”

 port should not be configured to be within the same IP subnet.  The 

Control

” port and “

IP Video

” port should also not be physically connected to the same network without 

proper network segmentation.

It is possible to access the unit's user interface via the “

IP Video

” port by using the IP address assigned 

to XC1.

Summary of Contents for Clearview 4:2 SD

Page 1: ...der H 264 to MPEG 2 SD Transcoder for up to 24xSPTS Channels Clearview 4 2 SD Quick Guide Blonder Tongue Labs Inc ISO 9001 2015 Certified P N 651245400A Rev 070921 All Rights Reserved Specifications subject to change without notice All trademarks are property of their respective owners ...

Page 2: ...1 To power the unit up connect the IEC line cord to the receptacle on the rear panel Then connect the other end to a 120 VAC power outlet The input power receptacle is equipped with a fuse holder and fuse SLO BLO 3 0 Amp 250V 2 WARNING For safe and reliable operation the ground pin of the power cord must be grounded properly IMPORTANT NOTE BEFORE YOU BEGIN The Key2License from Technicolor is requi...

Page 3: ...be found using the search box in the Start Menu or for Windows 8 x the Start Screen b Once open click on Change Adapter Settings on left hand side of the window c Right click on the Local Area Connection and then click on the Properties d A dialog box entitled Local Area Connection Properties will appear In this box double click on the Internet Protocol Version 4 TCP IPv4 e A dialog box entitled I...

Page 4: ...tatus tab Status Page Full View Step 3 Login to the Controller An Ethernet Cable should be connected between your PC and the Control port on the unit Open a Web browser Chrome or Firefox recommended and type http 172 16 70 1 in to your web browser to view and configure your Clearview 4 2 SD Enter the username Admin and pass as the password and click LOG IN ...

Page 5: ...anscoder used The page also features a recent logged message box beneath the main status area which shows the 10 most recent entries within the Event Log To see a more in depth log of event messages click the Log tab located on the right side of the navigation menu at the top System Page Full View The following Ethernet Settings can be changed IP address Subnet Mask Default Gateway and the Primary...

Page 6: ...s in the Video Audio Pipeline Settings table located on the right side The corresponding tab is also highlighted for persistent indication of the Transcode pipeline settings currently being shown Step 5 Transcoder Configuration Transcoders Settings The final information to setup within the unit is located in the Transcoders Settings tab Transcoders Settings Page Example Pipeline Status States Ligh...

Page 7: ... 0 3 The Management PC is configured to be at 192 168 3 5 with a subnet mask of 255 255 0 0 Note The subnet mask of the Video Source Sink device must be configured to be on the same subnet mask as the Management PC Accessing devices from the Management PC To access the Video Source Sink device go to http 192 168 3 18 To access the Clearview 4 2 SD unit go to http 192 168 6 71 Note Additional Clear...

Page 8: ...entation Updates Download the latest User Manual PDF by visiting our website Navigate to the product page by entering the full Model Name or Stock Number in the search field Upon reaching the product page the User Manual download link will be located beneath the product image Firmware Updates are available under Tech Support in the Resources section of the website General instructions for the FTP ...

Reviews: