2 Clearview 4:2 12

Quick Guide

Product Introduction

The Clearview 4:2 12 receives up to twelve (12) H.264 AES-128 encrypted IP channels from the Technicolor COM3000/2000 

devices.
The Clearview 4:2 12 decrypts the AES-128 content into clear IP, transcodes the decrypted H.264 content into MPEG-2, 

while preserving the “forensic watermarking” and returns the content to the Technicolor COM3000/2000 devices as clear IP.

Before You Begin

Unpacking the Unit

You will find the following Items in the box:

• 

Clearview 4:2 12 (QTY=1)

• 

Power Cord with IEC C13 line socket and 3-pin Type B NEMA 5 plug (QTY=1)

Features:

• Decrypts AES-128 encrypted H.264 video content
• IP input that supports up to 12 SPTS H.264 HD programs
• IP output supports up to 12 SPTS MPEG-2 HD programs
• 

Preserves embedded watermarking on outbound MPEG-2 

video content

• Easy-to-use GUI for monitoring & control
• 12 front panel Status LEDs, one for each program stream
• One front panel Temperature LED

IMPORTANT NOTE BEFORE YOU BEGIN!

The Key2License from Technicolor is required and MUST be installed on the COM3000/2000 

unit prior to setup of this unit. See 

Section 3

 of the User Manual for more information.

The Clearview 4:2 is designed to be installed in a standard 19-inch (483 mm) rack (EIA 310-D, IEC 60297, and DIN 41494 SC48D).  

To install, secure the unit's front panel to the rack by inserting four (4) machine screws, with cup washers, through the 

four (4) mounting holes in the front panel. A 1RU open space is recommended above the unit for ventilation.

Step 1: Setup and Install of the Unit

1

DO NOT BLOCK THE UNIT'S AIR INTAKE OR AIR DISCHARGE OPENINGS

The Unit performance will be degrated without proper ventilation.

Excessive heat will shorten the life of the unit.

To power the unit up, connect the IEC line cord to the receptacle on the rear panel. Then connect the other end to a 

120 VAC power outlet.  The input power receptacle is equipped with a fuse-holder and fuse (SLO-BLO, 3.0 Amp, 250V).

2

WARNING

For safe and reliable operation, the ground pin of the power cord must be grounded properly.

Summary of Contents for Clearview 4:2 12

Page 1: ...hannels H 264 to MPEG 2 HD Transcoder for up to 12 SPTS Channels Clearview 4 2 12 Quick Guide Blonder Tongue Labs Inc ISO 9001 2015 Certified P N 651245400A Rev 070921 All Rights Reserved Specifications subject to change without notice All trademarks are property of their respective owners ...

Page 2: ...front panel Temperature LED IMPORTANT NOTE BEFORE YOU BEGIN The Key2License from Technicolor is required and MUST be installed on the COM3000 2000 unit prior to setup of this unit See Section 3 of the User Manual for more information The Clearview 4 2 is designed to be installed in a standard 19 inch 483 mm rack EIA 310 D IEC 60297 and DIN 41494 SC48D To install secure the unit s front panel to th...

Page 3: ...be found using the search box in the Start Menu or for Windows 8 x the Start Screen b Once open click on Change Adapter Settings on left hand side of the window c Right click on the Local Area Connection and then click on the Properties d A dialog box entitled Local Area Connection Properties will appear In this box double click on the Internet Protocol Version 4 TCP IPv4 e A dialog box entitled I...

Page 4: ...ab located on the right side of the navigation menu at the top Step 4 Basic Configuration System Status Once you are logged into the unit you will be presented with the System Status page Status tab Status Page Full View Step 3 Login to the Controller An Ethernet Cable should be connected between your PC and the Control port on the unit Open a Web browser Chrome or Firefox recommended and type htt...

Page 5: ...tem tab to change the System Settings including unit identification and network settings System Page Full View The following Ethernet Settings can be changed IP address Subnet Mask Default Gateway and the Primary and Secondary DNS In addition the network settings for each transcoder slave are individually configurable Click Apply Settings in order to save new or changed settings This section allow...

Page 6: ...t is located in the Transcoders Settings tab Transcoders Settings Page Example Transcoders Status The information shown on this screen indicates the status of each transcoder A visual status of the pipeline is also shown on the left side When hovering over a Transcode block the corresponding status table highlights Transcoders Status Page Visual and Informational Status Pipeline Status States Ligh...

Page 7: ... 0 3 The Management PC is configured to be at 192 168 3 5 with a subnet mask of 255 255 0 0 Note The subnet mask of the Video Source Sink device must be configured to be on the same subnet mask as the Management PC Accessing devices from the Management PC To access the Video Source Sink device go to http 192 168 3 18 To access the Clearview 4 2 12 unit go to http 192 168 6 71 Note Additional Clear...

Page 8: ...entation Updates Download the latest User Manual PDF by visiting our website Navigate to the product page by entering the full Model Name or Stock Number in the search field Upon reaching the product page the User Manual download link will be located beneath the product image Firmware Updates are available under Tech Support in the Resources section of the website General instructions for the FTP ...

Reviews: