28 EQAM-420A
Instruction Manual
System Watchdog: automatically resets unit’s Operating System if or when it is required.
System Reboot: allows the user to reboot EQAM-420A.
10/100 IP Address: is the static IP address that is assigned to the unit. It allows the user to access the unit via the web
interface. The factory default IP address is 172.16.70.1.
10/100 Subnet Mask: is the Subnet Mask address of the unit. It allows the user to access the unit from another
network via the web interface. The factory default Subnet Mask is 255.255.255.0.
10/100 Default Gateway: is the gateway address of unit. It allows the user to access the unit from another network
via the web interface. The factory default Subnet Mask is 172.16.70.254.
1 GIGE IP Address: is the static IP address assigned to the Gigabit Ethernet (GigE) port. The factory default value is
192.168.253.1.
Error Log Destination: is the IP address of the remote server, to which Syslog sends the activities recorded by EQAM-
420A for monitoring and troubleshooting purposes. The factory default value is 172.16.70.2.
Log Destination Port #: is the Error Log Destination port to which a duplicate of the error messages created by the
unit can be forwarded for monitoring and troubleshooting purposes. The factory default and recommended value is
514.
SNMP R/W Community Name: is the password for the read/write SNMP communication that allows operator to view
and edit "get" or "set" parameters of the EQAM-420A. The factory default value is “pass”.
SNMP Read Community Name: is the password for the read-only SNMP communication that allows operator to view
the "get" parameter of the EQAM-420A. The factory default value is “pass”.
SNMP Destination: This is the IP address for the SNMP server. The factory default value is 172.16.70.2.
SNMP Destination Port #: is the SNMP destination Port from which the operator can monitor different parameters
of the EQAM-420A unit when used in conjunction with an SNMP server. The factory default value, which cannot be
modified, and industry standard is 161.
Time Server IP: is the IP address for the Time Server from where the unit can obtain its clock reference (see Section
6.9 for details). The factory default value is 172.16.70.2.
Stuffing Packet Payload Data: is the number of bits of null packets that can be inserted in the data. The range is 00
to FF.
Syslog Errors: is to enable/disable EQAM-420A to forward error messages (in red font) to an SNMP syslog. The factory
default value is disabled.
Syslog Informational: is to enable/disable EQAM-420A to forward information messages (in blue font) to an SNMP
syslog. The factory default value is disabled.
Syslog Feedback: is to enable/disable EQAM-420A to forward feedback or confirmation messages (in green font) to an
SNMP syslog. The factory default value is disabled.
16
17
18
19
20
21
22
23
24
25
26
27
28
Remember to click on the SAVE button to apply the new values/configurations.
14
15
12
13
Make sure the IP address assigned to 10/100 IP Address and 1 GigE IP Address (see & above)
are in different network address ranges or sub-networks.
Example: If the 10/100 IP Address = 172.16.70.100,
10/100 Subnet Mask = 255.255.255.0, and
1 GigE IP Address = 172.16.70.110,
then you will not be able to communicate with the unit as the 10/100 Remote Control and Data (1
GigE) ports (see & of Section 2.2 for details) belong to the same subnet.
Therefore, assign 1 GigE IP Address = 192.168.253.1 or 172.16.100.98 to ensure that the
10/100 Remote Control and Data (1 GigE) ports belong to different address ranges (when using
192.168.253.1) or subnets (when using 172.16.100.98).
17