Heater (Open spiral wire): 
A 2500W two circuit open spiral wire type heater is driven by the 2 relays. A manual resettable 
thermostat  is  used  on  these  heater,  in  order  to  provide  IEC  safety  rules  accordingly.  This 
manual  resettable  thermostat  cut  the  heater  power  at  160°C  and  can  be  resetted  by  the 
pressing the button on thermostat, so heater can be used after a failure bacause of thermostat 
is open curcuit.  
 
The  second  temperature  regulating  element  on  the  heater  is  NTC.  When  the  desired 
temperatures  is  reached,  electronic  control  card  reads  the  resistance  of  NTC  and  if  the 
prescribed resistance ( and hnce temperature) is reached, the heater is switched off. 
 
This mechanical thermostat operates only;  
 

 

 

Locked tumble, 

 

 

 

 

Locked rotor, 

 

 

 

Broken fan, 

 

 

 

Filter and condenser is full, conditions. 

 

Warning:  When  NTC  is  broken  down,  the  heater  is  changed  by  the  new  heater.  If 
thermostat  is  open  curcuit,  the  same  heater  will  be  used  by  pressing  the  button  on 
thermostat.  

 

 
Door Lock : 
Locking and unlocking mechanism of the door lock used in the dryer is a mechanical type of the 
door lock. When the door pushed, the door is locked and the door is closed. When the pull from 
the handle of the door, it will be open with a suitable force.  

 

 

Especially, door lock and hinge sould be checked if there is a locking problem.

 

 

 

Door Switch : 
 
The current is sent to electronic card and motor by the door switch. By this way  when door is 
opened due to any reason, motor stops automaticlly. However because of EN&IEC safety rules, 
when the door is closed again, motor does not start. It is necessary to press start/pause/cancel 
button to restart dryer.  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for TKF 8439

Page 1: ...Tumble Dryer Service Handbook 1 INDEX 1 Technical Specifications 2 Components and Dryer Principals 3 Control System 4 Service test program 5 Fault algorithms 6 Wiring schematics 7 Exploded views 8 Sp...

Page 2: ...Ar elik Blomberg 2009 ARES MLCD 8 kg Tumble Dryer Service Handbook 2...

Page 3: ...imensions 1 2 1 Height mm 846 1 2 2 Depth mm 598 1 2 3 Width mm 595 1 3 Package 1 3 1 Material PE bag Shrink pack 1 3 2 Supporter Polystrofoam Wood 1 3 3 Dimensions Height mm 880 Depth mm 660 Width mm...

Page 4: ...eater 1 9 1 Type Open wire spiral heating element 1 9 2 Nominal Power Voltage W 230Vac 1600 900 2500 5 1 9 3 Resistance ohm 1600 W 1 level power 57 63 ohm 5 900 W 2 level power 32 41ohm 5 Warning NTC...

Page 5: ...nual resetting thermostat is checked from the terminals while heater is on the dryer If manual resetting thermostat is open curcuit the button is up and the heater does not work If the button is up po...

Page 6: ...or opening mm 395x320 1 12 5 Proces air flow m3 h 190 1 12 6 Maximum loading Capacity Cotton kg 8 Delicate Synthetic kg 4 1 13 Control System Specifications 1 13 1 On off Button 250 V 16 4 A 1 13 2 Do...

Page 7: ...ture sensor are used on electronic controlled dryers one is located after the door filter in suction canal other is located in the heater As the temperature of the surrounding of NTC increases its res...

Page 8: ...chanical thermostat operates only Locked tumble Locked rotor Broken fan Filter and condenser is full conditions Warning When NTC is broken down the heater is changed by the new heater If thermostat is...

Page 9: ...via 2 poles asenkron motor Motor turns 2750 prm ans has a 9 uF capacitor Asenkron motor is controled by two Control panel two relays one of them for direction other one is for energy that placed in co...

Page 10: ...ndenses Then the air is heated again this circulation continues until the drying process finished Condensing occurs by cooling the air To achieve that a secondary fan circulates the air in the condens...

Page 11: ...Ar elik Blomberg 2009 ARES MLCD 8 kg Tumble Dryer Service Handbook 11 3 Control System...

Page 12: ...Ar elik Blomberg 2009 ARES MLCD 8 kg Tumble Dryer Service Handbook 12 Symbol Explanations...

Page 13: ...Ar elik Blomberg 2009 ARES MLCD 8 kg Tumble Dryer Service Handbook 13...

Page 14: ...Ar elik Blomberg 2009 ARES MLCD 8 kg Tumble Dryer Service Handbook 14...

Page 15: ...Ar elik Blomberg 2009 ARES MLCD 8 kg Tumble Dryer Service Handbook 15...

Page 16: ...Ar elik Blomberg 2009 ARES MLCD 8 kg Tumble Dryer Service Handbook 16...

Page 17: ...extra programmes available Warning Additional programmes may differ according to the model of your machine Mini 35 You can use this programme to dry your cottonlaundry that you have spun at high spee...

Page 18: ...atin type underwear nightgown garments for upper body pajamas with the word dryable in the washing instructions Products with a high accessory content such as lace veil stone beads and wires and produ...

Page 19: ...t Program Step 1 Program selector is set as wool refresh and while pressing the cancel audio warning button turn on dryer After 3 seconds service test program starts In this program start pause cancel...

Page 20: ...mberg 2009 ARES MLCD 8 kg Tumble Dryer Service Handbook 20 Step 3 On the display the supplying voltage and the software version is shown Step 4 The values of the heater NTC and door NTC are shown on t...

Page 21: ...the sensor if the sensor are open circuit It can not be passed to the next steps till the sensors are open circuit Double beep is heard when the Start Pause button is pushed One beep is heard when the...

Page 22: ...Ar elik Blomberg 2009 ARES MLCD 8 kg Tumble Dryer Service Handbook 22 Step 7 First level heater 1600W is on Step 8 The dryer stops...

Page 23: ...nsor short circuit by touching the sensor plate Check the if the sensor are short circuit It can not be passed to the next steps till the sensors are short circuit Double beep is heard when the Start...

Page 24: ...Ar elik Blomberg 2009 ARES MLCD 8 kg Tumble Dryer Service Handbook 24 Step 10 The dryer stops Step 11 The pump is activated...

Page 25: ...8 kg Tumble Dryer Service Handbook 25 Step 12 The last 3 failure codes are shown on the display in turns There is no necessary to push start pause button When it is pushed it goes back to the first st...

Page 26: ...reture is over limit 8 ERROR_CLEAN_FILTER Filter is full with fuzz 9 ERROR_BROKEN_STRAP V belt is broken 10 ERROR_TEMPERATURE_DIFFERENCE The temparature difference between heater NTC and Door NTC is 6...

Page 27: ...ode Step 1 In the Service Mode when the LCD shows Software version for example u07 Step 2 Turn the rotary to Time programme Step 3 Press the Start Pause Cancel button then you will be in the New error...

Page 28: ...o pass to step 4 01 Shows the last occured error If Start Pause Cancel button is not pressed then every definition in 4th step will be displayed for 2 sec intervals Pr xx Program in which error occurs...

Page 29: ...07 Error Code 7 has occured User can check the definition of error from Failure Codes Step 5 If Start Pause Cancel button is pressed once the next error will be seen By pressing Start Pause Cancel bu...

Page 30: ...Error 02 Error before Last one 20 20th Error Program Definition Pr 00 Cotton Extra Dry Pr 01 Cotton Cupboard Dry Pr 02 Cotton Iron Dry Pr 03 Synthetic Cupboard Dry Pr 04 Synthetic Iron Dry Pr 05 Jeans...

Page 31: ...the electrical connections Connect the power supply YES NO Check the electricity on the main control card YES Change the main card NO Check the on off switch connections Check the connections NO Chec...

Page 32: ...r drying time is too long Check the heaters relays Reset the heater Is the heater thermic NC on Check the software change the main card Change the heater Check the heater connections YES NO YES NO YES...

Page 33: ...can not be set Are the values on the program selector potentiometer correct Potentiometer YES NO Each turn of rotary knob there should be 1Kohm increase If it is not change the rotary Is the Rotary ma...

Page 34: ...drum is not rotating Is V belt on Fix the V belt NO Are the motor relays running YES Check the software change the main control card NO Are motor winding resistance are correct Motor heating problem...

Page 35: ...ik Blomberg 2009 ARES MLCD 8 kg Tumble Dryer Service Handbook 35 Program doesn t progress although the tank is empty Is the overflow switch is broken YES NO Fix or change the overflow switch Check the...

Page 36: ...Ar elik Blomberg 2009 ARES MLCD 8 kg Tumble Dryer Service Handbook 36 6 Wiring Schematics Blomberg AB09 Condenser MLCD Wiring Schematics...

Page 37: ...Ar elik Blomberg 2009 ARES MLCD 8 kg Tumble Dryer Service Handbook 37 Blomberg AB09 Condenser MLCD Cable Schematics...

Page 38: ...Ar elik Blomberg 2009 ARES MLCD 8 kg Tumble Dryer Service Handbook 38 7 Expoled Views 8 Spare Parts List 9 Demounting...

Reviews: