Arçelik/Blomberg 2009 ARES MLCD 8 kg
Tumble Dryer Service Handbook
26
Failure Codes :
Failure
code
Description
Explanation
0
ERROR_CONSTANT_VALUE
The same valued is read
for 5 minutes
1
N/A
N/A
2
ERROR_TANK_FULL
Water tank is full
3
ERROR_ROTARY
Rotary is broken
4
ERROR_HEATER_NTC
Heater NTC is shot circuit
or open circuit.
5
ERROR_DOOR_NTC
Door NTC is shot circuit or
open circuit.
6
ERROR_HEATER_HIGH_TEMPERATURE
Heater tempareture is
over limit.
7
ERROR_DOOR_HIGH_TEMPERATURE
Door tempareture is over
limit.
8
ERROR_CLEAN_FILTER
Filter is full with fuzz
9
ERROR_BROKEN_STRAP
V-belt is broken
10
ERROR_TEMPERATURE_DIFFERENCE
The temparature
difference between heater
NTC and Door NTC is 60
degrees
11
ERROR_HEATER_TEMPERATURE_RAPIDLY_INCREASED
Heater temparature is
rapidly increased between
15 and 25 seconds.
12
ERROR_DOOR_OPENED
The door is opened during
the cycle.
13
ERROR_HIGH_VOLTAGE
The voltage is over 265V .
14
ERROR_LOW_VOLTAGE
The voltage is
under 165V .
15
ERROR_MAX_TIME
If the humidity sensor
drying programs reaches
its maximum time limits.
16
ERROR_DRUM_IDLE
Only beginning of sensor
drying programs.
17
ERROR_Program_ROTARY
If the Rotary is turned
during Run Mode.
Summary of Contents for TKF 8439
Page 2: ...Ar elik Blomberg 2009 ARES MLCD 8 kg Tumble Dryer Service Handbook 2...
Page 11: ...Ar elik Blomberg 2009 ARES MLCD 8 kg Tumble Dryer Service Handbook 11 3 Control System...
Page 12: ...Ar elik Blomberg 2009 ARES MLCD 8 kg Tumble Dryer Service Handbook 12 Symbol Explanations...
Page 13: ...Ar elik Blomberg 2009 ARES MLCD 8 kg Tumble Dryer Service Handbook 13...
Page 14: ...Ar elik Blomberg 2009 ARES MLCD 8 kg Tumble Dryer Service Handbook 14...
Page 15: ...Ar elik Blomberg 2009 ARES MLCD 8 kg Tumble Dryer Service Handbook 15...
Page 16: ...Ar elik Blomberg 2009 ARES MLCD 8 kg Tumble Dryer Service Handbook 16...