12 / EN
Induction Hob / User Manual
3
Installation
Mains
Connection
Cable diameter
Protection calibre Flexible conduit
220-240 V~ 50/60
Hz
2 Phases
3 x 10 AWG
40 A
¾”
Use only ul listed or csa approved components
3.5Connectionofthecooktop
Use the brass bridges which are in the connection
box to bridge terminals 1-2 and terminals 4-5.
Connect line 1 to the terminal 1, line 2 to the
terminal 4 and the ground to terminal
A
Caution!
Ensure that the cables
are correctly inserted and tightly
screwed down.
C
We cannot be held responsible for
any incident resulting from incor-
rect connection or which could arise
from the use of an appliance which
has not been earthed or has been
equipped with a faulty earth con-
nection.
3.6Positionofnameplate
The nameplate is located under the cooktop, as
shown on the picture below. When ordering parts
for or making inquiries about your cooktop, always
be sure to include the model and serial numbers
and a lot number or letter from the serial plate on
your cooktop.
Nameplate label