Installation
17
Final Check and Adjustments
BEFORE SWITCHING THE APPLIANCE ON
Before applying power to the unit for the first time,
check for the following conditions:
j
All electrical safety provisions have been ad-
hered to and the electrical connections are
correct.
j
Water is connected, turned on and all of the
connections are water tight.
j
Check all gas fittings at the site with leak
detection solution.
NOTE:
COS-8G and BCS-8G units only
--- The
first time the unit is turned on, or after the
unit has been OFF for 5 hours and then
turned on, it will automatically flush the
steam generator for a period of 75 sec-
onds. The steam generator will then fill to
the proper water level. The unit is now
ready for operation.
DOOR ADJUSTMENT
The door catch may be adjusted in two directions,
in and out, and up and down, using the following
procedure:
1. Adjust catch up and down by loosening the
two bolts holding the catch to the face of the
unit (A).
2. Make adjustments so that the leading face of
the catch is centered in the opening of the
handle assembly.
3. Tighten the bolts so that there is no further
movement.
4. Adjust catch in and out by loosening the bolt
on the top of the catch (B).
5. The adjustment face is stepped so that move-
ment is limited with the bolt tightened properly.
6. The adjustment is correct when the door closes
firmly and no steam leaks from the gasket.
The hinges can also be adjusted as follows:
1. Be certain the catch is adjusted properly.
2. Adjust hinges so that the door back and the
unit face are parallel (C).
3. The adjustment is correct when no steam
leaks through the gasket.
COS-8G shown
C
Oven
Door
A
B
Figure 14