Installation
9
Utility Connections
STEAM CONNECTION
NOTE: COS-8GDS only.
Connect the appliance to a 200 psi maximum ex-
ternal steam source per local or state codes. The
steam must be clean, potable and fit for human
consumption. Failure to connect this appliance to
a suitable steam source will revoke the approval of
NSF.
ELECTRICAL CONNECTION
Before making any electrical connections to these
units, check that the power supply is adequate for
the voltage, amperage, and phase requirements
stated on the rating name plate mounted on the
unit.
Wiring diagrams are located on the inside of the
louvered side panel.
All units are equipped for operation on 115V 15
amp 1
Φ
60Hz., 2 conductor cable with ground.
Wiring from the power source to this unit must be
a minimum of #16 AWG CU. stranded wire or larg-
er.
NOTE: DISCONNECT THE POWER SUPPLY TO
THE UNIT BEFORE SERVICING!
WARNING!!
This appliance is equipped with a 115V,
three-prong (grounding) plug for your
protection against shock hazard and
should be plugged directly into a properly
grounded three-prong receptacle. DO
NOT cut or remove the grounding prong
from this plug.
U.S. and Canadian installation
All units, when installed, must be electrically
grounded in accordance with local codes or in the
absence of local codes, with the
National Electrical
Code, ANSI/NFPA 70---Latest Edition and/or Cana-
dian Electrical Code CSA C22.1
as applicable.
General Export Installations
Installation must conform with Local and National
installation standards. Local installation codes
and/or requirements may vary. If you have any
questions regarding the proper installation and/or
operation of your unit, please contact your local
distributor. If you do not have a local distributor,
please call Blodgett Combi at 0011-802-860-3700.
WARNING!!
Improper electrical installation will invali-
date your warranty.