background image

BLODGETT

44 Lakeside Avenue, Burlington, VT 05401

Toll Free: (800) 331-5842 • Phone: (802) 860-3700 • Fax: (802) 864-0183

CB-E ELECTRIC STEAM BOILER

SHORT FORM SPECIFICATIONS

Provide Blodgett model CB24-24E (24kW), CB24-36E (36kW), CB24-42E (42kW) or CB24-48E (48kW) 24” wide electric steam boiler cabinet, or CB36-24E (24kW), CB36-36E (36kW),
CB36-42E (42kW) or CB36-48E (48kW) 36” wide electric steam boiler cabinet. Polished stainless steel cabinet base shall be of modular design to match other Blodgett steam equipment.
Unit shall have 6” (152mm) stainless steel legs and adjustable bullet feet, reinforced stainless steel counter top and hinged doors with magnetic latches. All piping shall be confined with-
in the cabinet. Unit shall be automatically filled with water and brought to pressure when power switch is turned on. Cold water condenser shall automatically condense exhausted steam
in water before releasing it to drain. Boiler controls shall include automatic water level, pressure gauge, water gauge glass, pressure control with pressure safety control, safety relief valve,
cathodic protector and CSD-1 secondary low water cut off. Boiler shall be ASME code stamped and National Board registered. Provide options and accessories as indicated.

WATER SUPPLY:

Water quality is a major factor affecting the performance of your steamer. If you
are unsure of water quality, consult a local water treatment specialist and have
the water analyzed. Your water supply must be within these general guidelines:

Total dissolved solids: Less than 60 PPM

Total alkalinity: Less than 20 PPM

Silica:

Less than 13 PPM

Chlorine:

Less than 1.5 PPM

pH Factor:

7.0 - 8.5

Water which fails to meet these standards should be treated by installation of a
water
conditioner. Failure or malfunction of this steamer due to poor water quality is not
covered under warranty.

WATER & DRAIN CONNECTIONS:

Drain

2” (51mm) IPS piped to open floor drain. No solid connection.
24” length before open air opening (no bends or elbows)

Cold Water

3/8” (10mm) tubing at 25-50 PSI (170-345 kPa)

Steam Take Off 3/4” IPS optional to operate adjacent equipment

POWER SUPPLY:

208, 220 or 240 VAC, 3 phase 60 Hz w/grounding wire

SHIPPING INFORMATION:

Approx. Weight:

CB24-24E 400 lbs. (181 kg)

CB24-42E 400 lbs. (181 kg)

CB36-24E 440 lbs. (200 kg)

CB36-42E 425 lbs. (193 kg)

CB24-36E 400 lbs. (181 kg)

CB24-48E 400 lbs. (181 kg)

CB36-36E 425 lbs. (193 kg)

CB36-48E 425 lbs. (193 kg)

Printed in U.S.A.

NOTE:

FOR COMMERCIAL USE ONLY

NOTE:

The company reserves the right to make substitutions of components without prior notice.

APPROVAL/STAMP

P/N S00021 Rev F (12/06)

MODEL

A

B

C

D

E

F

G

H

J

K

L

M

N

P

24” models 8.75[222]

5.75[146] 16.75[425]

23[584]

8.75[222]

3.5[89]

10.5[267]

2.5[64]

11.12[283]

2.75[70]

2.5[64]

13[330]

19.75[502] 4.75[121]

36” models 8.75[222]

5.75[146] 16.75[425]

23[584]

18[457]

3.5[89]

10.5[267]

2.5[64]

11.12[283] 4.75[121]

2.5[64]

21.25[540] 19.75[502] 6.75[171]

AMPS PER LINE

kW

Phase 208V 220V 240V 380V 415V 480V

24

1

115.4 109.1 100.0

N/A

N/A

N/A

3

66.6

62.9

57.7

36.5

33.4

28.9

36

3

99.9

94.5

86.6

54.7

50.1

43.3

42

3

116.6 110.2 101.0

63.8

58.4

50.5

48

3

N/A

N/A

115.5

72.9

66.8

57.7

Reviews: