5
INSTALLATION
PLUMBING SPECIFICATIONS
WATER
Water pressure
36.26 PSI (250 kPa, 2.5 bar) during Combi Wash
21.76 PSI (150 kPa, 1.5 bar) when Combi Wash is not active
40(min)-50(max) PSI supply pressure
Water connection
3/4” garden hose cold water
Water quality requirements
TDS: 40-125 ppm
Hardness: 35-180 ppm
Chlorides: <25 ppm
Silica: <13 ppm
Chlorine: < 0.2 ppm
Chloramine: < 0.2 ppm
pH: 7.0-8.5
DRAINAGE
Drain type
Atmospheric Vented Drain
Drain connection
2.00” (50.8mm) Copper
1.57” (40mm) Copper - mini combi ovens
Maximum water drain temperature 140ºF (60ºC)
ELECTRICAL RATINGS
Model
Voltage
kW
Hz
Phase
Max Load (amps)
Hood
BLCT-6E-H
208
6.9
50/60
1
35
115V, 50/60 Hz,
1 phase, 15 amp
240
9.2
50/60
1
39
208
6.9
50/60
3
20
240
9.2
50/60
3
24
BLCT-10E-H
208/230/240
10.4/12.7/13.8
50/60
3AC
34
115V, 50/60 Hz,
1 phase, 15 amp
10.4/12.7/13.8
50/60
3NAC
34
400/415
12.7/13.8
50/60
3NAC
20
12.7/13.8
50/60
3AC
20
440/480
10.4/12.4
50/60
3AC
18
BLCT-61E-H
208
9
60
3
25
115V, 50/60 Hz,
1 phase, 15 amp
240
9
60
3
22
480
9
60
3
11
BLCT-62E-H
208
21
60
3
59
115V, 50/60 Hz,
1 phase, 15 amp
240
21
60
3
51
480
21
60
3
26
BLCT-101E-H
208
18
60
3
50
115V, 50/60 Hz,
1 phase, 15 amp
240
18
60
3
44
480
18
60
3
22
BLCT-102E-H
208
27
60
3
75
115V, 50/60 Hz,
1 phase, 15 amp
240
27
60
3
65
480
27
60
3
33
Utility Specifications