ProBLeM

PotentiaL cause

soLutions

Faucet set

Handspray is weak/

no flow

Clog at handspray

Remove handspray/clear debris/retest

Clog in diverter

Clean out stem/diverter body/retest

Backflow preventer in wrong location

Bellevue (next to handspray); Montage (near diverter)

Low pressure in house

Make sure main shut off is open completely

Wall shut off valves not fully open

Open wall supply valves

No flow at all from 

spout/handspray

Wall supply valves are closed

Open wall supply valves

Diverter has plastic half moon flow 

diverter installed backwards

Take apart diverter stem/re-position part

Water is not completely 

diverted

Handle not completely turned

Test diverter handle in full left to right range of motion

Trim handle not properly installed

Check handle position to allow for full 180º range of 

motion

Diverter stem is clogged

Remove stem/clean diverter body/retest

Water leak near 

diverter on tub deck

Stem not tightened enough in 

diverter

Tighten diverter stem to diverter body

Water leak near valve 

on tub deck

Hot/cold cartridge not tight enough 

in valve body

Tighten cartridge in valve body

Water leaking from 

handspray connection

Missing gasket in between hose and 

handspray

Install gasket and retest

Teflon tape was not used on threads Install teflon tape on threads and retest

Fine crack in plastic threads on 

handspray

Replace handspray

Water leaking from 

handspray flex hose

Flex hose damaged inside

Replace flex hose

Diverter valve trim spins Broken stem/shaft

Replace stem/shaft.

Locking nuts not adequately 

tightened

Remove trim and tighten locking nuts

Hot/cold valve or spout 

trim turns more than 90º

Locking nuts not adequately 

tightened

Remove trim and tighten locking nuts

Door/hanDLe

Leaky door

Door handle not completely shut

Engage handle fully/retest

Dirty door seal/dirty door jamb

Wipe seal/wipe jamb/retest

Door seal ripped/torn/damaged

Replace door seal

Tub not level/plumb

Make sure tub is level front to back and side to side

All six feet are not touching the 

ground

Make sure all six feet are on ground and secure

Door not sealing/not shut tight 

enough

Look for daylight through seal/tighten handle/retest

extension Kit

Extension kit doesn't fit 

properly

They are rough fit/usually need some 

adjustment

Installer can grind or cut to make fit/seal with silicone

Drain sYsteM

Loose hand control

Set screw not tight enough

Gently tighten set screw with 8mm box wrench/pliers

Summary of Contents for B3252HC

Page 1: ...848 B2851 B2948 B3048 B3052 B3054 B3150 B3153 B3060 B3260 B3052HC B3252HC B3355 B3555 B3237 B305546 B315546 B306022 save these instructions Image shown is a dual system tub This manual also covers Bli...

Page 2: ...3 Supply Drain Plumbing Connection 4 Electrical Connection 5 Test C Finishing Work 1 Extension Panel Finish 2 Surround Installation 3 Trim 4 Final Seal table of contents POST INSTALLATION 20 A Clean U...

Page 3: ...ns Please completely read this manual before starting any installation work DANGER Indicates a definite hazard likely resulting in bodily harm serious injury or death WARNING Indicates a potential haz...

Page 4: ...being pushed there is a ground current flowing indicating the possibility of an electric shock If this should occur do not use this hydromassage bathtub Disconnect the hydromassage bathtub and have t...

Page 5: ...ained by the driver terminal you will have to use that same box to send it back 2 Carefully inspect the entirety of the gel coat surface for cracks spidering gouges etc 3 Next carefully inspect the st...

Page 6: ...umbing connections should be made by a qualified licensed contractor 1 Inspect Site for Existing Damage It is very important to make a thorough inspection of the installation site before any work is s...

Page 7: ...that the installation conforms to all applicable state and local codes Before any plumbing work is started check the current home water pressure at the tub location The manufacturer s recommended rang...

Page 8: ...thirds 2 3 hot water to one third 1 3 cold water Since the typical water requirement to fill a regular size Bliss Tub model is 40 to 50 gallons depending on the user s size roughly 30 to 35 gallons o...

Page 9: ...ALK IN BATHTUB PREPARATION 1 Faucets Faucets are thoroughly inspected for appearance and function by our factory trained technicians For best results install the faucet set on the deck in the order it...

Page 10: ...LARGE RUBBER WASHER 5 HAND SPRAY FLEX HOSE CHROME 1 19 BACKFLOW PREVENTER CHECK VALVE 1 TRIM CAP SET SCREW 4 2 PARTS LIST 12a DIVERTER VALVE CAP 1 12b INTERNAL SPACER 1 12c DIVERTER SHAFT WITH CARTRID...

Page 11: ...n operation The edges of the overflow wall fitting can be filed as needed to improve knob function Use 1 PVC pipe to connect the overflow outlet to the sanitary tee door drain tie in and drain shoe as...

Page 12: ...AT THE LOW POINTS copyright Bliss Tubs 2015 copyright Bliss Tubs 2015 copyright Bliss Tubs 2015 Drain Shoe Check Valve 1 PVC Door Drain Tie In Door Drain Tubing TOP VIEW Door Drain Tub Drain Check Va...

Page 13: ...ld be against the left wall as shown below When installing a flange down tub the extension panels are universal and can be installed on either end of the tub INSTALLATION Extension Panel Front Piece E...

Page 14: ...hen screws or bolts can be used to join the extension panel to the tub flange IMPORTANT DO NOT ATTACH THE PANEL YET JUST GET EVERYTHING PRE FIT Bracing the extension panels Attach a support to the wal...

Page 15: ...ORTANT TO LEVEL THE TUB FRONT TO BACK AND SIDE TO SIDE AND TO HAVE ALL OF THE TUB FEET TOUCHING THE GROUND FAILURE TO DO SO MAY RESULT IN DOOR LEAKS FLOODING AND OR BOWING OF THE TUB FRAME AND SHELL B...

Page 16: ...crete subfloor use bolts and steel strapping over the frame to secure the tub to the floor or use heavy duty masonry screws that won t loosen over time Both flange up tubs and flange down tubs can be...

Page 17: ...e Plumber s Tape Tub Body Tub Tile Flange Stainless Steel Frame Silicone Optional Molding Mastic or Construction Adhesive copyright Bliss Tubs 2015 copyright Bliss Tubs 2015 copyright Bliss Tubs 2015...

Page 18: ...age AND Flange Down New Tile Surround Refer to Detail D on Previous Page A walk in bathtub with no tile flanges offers installers flexibility in the installation process Walk in bathtubs that are full...

Page 19: ...ted in the floor according to local plumbing codes 6 Now test both the faucets and the drain function checking for any leaks at any of the plumbing connections It is the responsibility of the contract...

Page 20: ...ill the tub with water to above the highest water jet if equipped 8 As the tub is filling continually check the door seal and all the plumbing for any leaks 9 Once the tub is filled test the systems a...

Page 21: ...ctor and their overall confidence in the installation Functional review with customer We highly recommend going over all the tubs functions with the customer once everything has been installed This wi...

Page 22: ...com Bliss Tubs acknowledges that no matter how stellar the quality of our product is the installation of the product still plays a paramount role in the satisfaction of the customer We appreciate the...

Page 23: ...loss of the system inconvenience due to loss damage to real or personal property or any other consequential damage Bliss Tubs will not be liable for any incidental expenses or material charges in conn...

Page 24: ...29 1 2 55 46 5 6 3 4 18 15 21 13 20 3 4 25 3 4 21 1 2 17 62 1 2 Y 100 95 90 315546 31 55 45 3 4 5 6 18 15 22 13 22 25 1 2 21 1 2 17 63 N 100 95 90 3237 31 1 2 37 1 2 38 1 2 N A 6 1 2 24 20 22 11 24 17...

Page 25: ...Fill Tub Occupant 120lbs 200lbs 250lbs Gallons 46gal 42gal 39gal B2848 Top Diagonal Dimension 55 Water Needed to Fill Tub Occupant 120lbs 200lbs 250lbs Gallons 57gal 52gal 49gal B2851 Top Diagonal Di...

Page 26: ...3 4 6 1 2 1 4 2 1 4 14 12 17 17 1 4 4 8 48 11 7 8 59 7 8 7 13 3 4 15 3 8 29 1 8 19 1 2 23 1 2 20 1 2 Top Diagonal Dimension 56 Water Needed to Fill Tub Occupant 120lbs 200lbs 250lbs Gallons 50gal 44ga...

Page 27: ...bs 200lbs 250lbs Gallons 53gal 48gal 45gal B3153 Top Diagonal Dimension 61 Water Needed to Fill Tub Occupant 120lbs 200lbs 250lbs Gallons 56gal 51gal 45gal B3260 Top Diagonal Dimension 68 Water Needed...

Page 28: ...eded to Fill Tub Occupant 120lbs 200lbs 250lbs Gallons 100gal 95gal 90gal B3555 Top Diagonal Dimension 65 Water Needed to Fill Tub Occupant 300lbs 350lbs 400lbs Gallons 72gal 67gal 62gal B315546 Top D...

Page 29: ...bs 200lbs 250lbs Gallons 63gal 58gal 55gal B3252HC Top Diagonal Dimension 60 Water Needed to Fill Tub Occupant 120lbs 200lbs 250lbs Gallons 65gal 60gal 57gal APPENDIX B2 DIMENSIONS Note Model dimensio...

Page 30: ...onal Dimension 49 Water Needed to Fill Tub Occupant 120lbs 200lbs 250lbs Gallons 46gal 42gal 39gal B306022 Top Diagonal Dimension 66 Water Needed to Fill Tub Occupant 120lbs 200lbs 250lbs Gallons 44ga...

Page 31: ...is on the opposite side than the drain location on the new walk in bathtub 1 Install drain shoe piece from the Bath Waste Overflow kit with the outlet facing the seat of the tub 2 Connect the reverse...

Page 32: ...ng Door Drain Tie in P Trap Street 45 Drain Shoe 90o ELL Overflow Shoe Photo Reverse Drain Plumbing Installed 4 The street 45 ell section of the reverse drain fitting should be pointing towards the fa...

Page 33: ...it 20 minute later You can delay the drying cycle as many times as you want INTEGRATED 20 MINUTES AUTOMATIC TIMER Integrated 20 minute automatic shut off timer on the system UP DOWN MODE ON OFF AIR C...

Page 34: ...for the purge cycle DELAYED DRYING CYCLE While the 1 minute drying cycle is activated if you press the ON OFF button during the drying cycle it will stop and will restart it 20 minute later You can d...

Page 35: ...ops ON OFF 2 NEXT COLOR Press Press to proceed to the next color On Rainbow cycle increases the speed ON WHEN PRESSED 3 PREVIOUS COLOR Press Press to return to the previous color On Rainbow cycle decr...

Page 36: ...er heater aroma chroma 9 4 12 5 0 05 0 55 22 5 2 x 15 4 Water heater ozone aroma 9 4 12 5 0 05 0 05 22 2 x 15 3 Water heater ozone chroma 9 4 12 5 0 05 0 55 22 5 2 x 15 3 Water heater ozone aroma chro...

Page 37: ...service technicians only Should maintenance be required the tub is equipped with two easily removable access panels one large for accessing beneath the seat and one small for accessing below the fauce...

Page 38: ...age system for 15 minutes then drain the tub Now refill the tub with warm water and run the system for another 15 minutes to rinse out the plumbing After the tub is fully drained use the hand held sho...

Page 39: ...verter stem to diverter body Water leak near valve on tub deck Hot cold cartridge not tight enough in valve body Tighten cartridge in valve body Water leaking from handspray connection Missing gasket...

Page 40: ...ser No power to blower Check GFCI outlet and circuit breaker Bad CAT 5 cable connection bad CAT 5 cable Check both ends are plugged in test a different cable Blower won t turn off Not pressing button...